User Instructions

SECURITY NOTATION SPEC
NO.
IT4061400-907
SEE PAGE INDEX
FOR THIS SHEET
REV LETTER
CAGE
CODE
58960
REV LTR
SEE THE TITLE PAGE FOR PROPRIETARY AND DATA RIGHTS NOTATIONS.
REV TEST SPECIFICATION PROCEDURE SPECIFICATION
LTR NO. OPR LIMITS C TEST DESCRIPTION SWITCH POS C WORK STEPS MFG LIMITS
AW/CRITICAL NOTATION
SUPPLEMENTS
A
-30
SECURITY NOTATION PAGE
15101-000 (REV 970213 BCAS ASF5900/ENG_SPEC.DOT) (REV 07/18/2000 -OFC97-DATA SERVICES) HONEYWELL INTERNATIONAL INC.
ENGINEERING
SPECIFICATION
A9.1 N/A (MAINT DATA OUT/AIR
DATA 1)
(MAINT DATA OUT/AIR
DATA 1)
N/A
Connect Xmtr 0 (Maint
Data Out) to Rcvr 0 (429
Air Data 1).
Perform initial setup in
accordance with table 7.
Perform initial setup in
accordance with table 7.
Modify receiver label:
Address Data
D220H FFAAH
Enter "modify memory
MDS word 1#0D220
FFAA"
Modify transmitter data:
Address Data
D210H AAAAH
D211H AAAAH
Enter "modify memory
MDS word 1#D210 thru
1#D211 to AAAA"
Enter "display memory
MDS word from 1#D200
to 1#D201"
Data should read as
follows:
Data should read as
follows:
Address
Address