User Instructions

SECURITY NOTATION SPEC
NO.
IT4061400-907
SEE PAGE INDEX
FOR THIS SHEET
REV LETTER
CAGE
CODE
58960
REV LTR
SEE THE TITLE PAGE FOR PROPRIETARY AND DATA RIGHTS NOTATIONS.
REV TEST SPECIFICATION PROCEDURE SPECIFICATION
LTR NO. OPR LIMITS C TEST DESCRIPTION SWITCH POS C WORK STEPS MFG LIMITS
AW/CRITICAL NOTATION
SUPPLEMENTS
A
-21
SECURITY NOTATION PAGE
15101-000 (REV 970213 BCAS ASF5900/ENG_SPEC.DOT) (REV 07/18/2000 -OFC97-DATA SERVICES) HONEYWELL INTERNATIONAL INC.
ENGINEERING
SPECIFICATION
A8.25 N/A Perform initial setup in
accordance with table 6.1.
Perform initial setup in
accordance with table 6.1.
N/A
Modify Memory:
Address Data
0D210H 0100H
0D211H 0000H
Enter "modify memory
MDS word 1#D210H to
0100H"
Enter "modify memory
MDS word 1#D211H to
0000H"
Read the following block
of memory: 0D200H thru
0D20FH.
Enter "display memory
MDS word from 1#D200H
thru 1#D20FH"
A8.26 0100H
0000H
Even locations
Odd locations
Even locations
Odd locations
0100H
0000H
A8.27 N/A Perform initial setup in
accordance with table 6.1.
Perform initial setup in
accordance with table 6.1.
N/A
Modify Memory:
Address Data
0D210H 0080H
0D211H 0000H
Enter "modify memory
MDS word 1#D210H to
0080H"
Enter "modify memory
MDS word 1#D211H to
0000H"
Read the following block
of memory: 0D200H thru
0D20FH.
Enter "display memory
MDS word from 1#D200H
thru 1#D20FH"
A8.28 0080H
0000H
Even locations
Odd locations
Even locations
Odd locations
0080H
0000H
A8.29 N/A Perform initial setup in
accordance with table 6.1.
Perform initial setup in
accordance with table 6.1.
N/A
Modify Memory:
Address Data
0D210H 0040H
0D211H 0000H
Enter "modify memory
MDS word 1#D210H to
0040H"
Enter "modify memory
MDS word 1#D211H to
0000H"
Read the following block
of memory: 0D200H thru
0D20FH.
Enter "display memory
MDS word from 1#D200H
thru 1#D20FH"
A8.30 0040H
0000H
Even locations
Odd locations
Even locations
Odd locations
0040H
0000H