User Instructions

SECURITY NOTATION SPEC
NO.
IT4061400-907
SEE PAGE INDEX
FOR THIS SHEET
REV LETTER
CAGE
CODE
58960
REV LTR
SEE THE TITLE PAGE FOR PROPRIETARY AND DATA RIGHTS NOTATIONS.
REV TEST SPECIFICATION PROCEDURE SPECIFICATION
LTR NO. OPR LIMITS C TEST DESCRIPTION SWITCH POS C WORK STEPS MFG LIMITS
AW/CRITICAL NOTATION
SUPPLEMENTS
A
-13
SECURITY NOTATION PAGE
15101-000 (REV 970213 BCAS ASF5900/ENG_SPEC.DOT) (REV 07/18/2000 -OFC97-DATA SERVICES) HONEYWELL INTERNATIONAL INC.
ENGINEERING
SPECIFICATION
SYNC ALT 1 FINE X-Z
SYNC ALT 1 FINE Y-Z
SYNC ALT 1 CRSE X-Z
SYNC ALT 1 CRSE Y-Z
SYNC ALT 2 FINE X-Z
SYNC ALT 2 FINE Y-Z
SYNC ALT 2 CRSE X-Z
SYNC ALT 2 CRSE Y-Z
1. Adjust the amplitude of
this signal to 9 V rms.
Read the digital value for
each synchro source,
using the following
procedure:
Read the digital value for
each synchro source,
using the following
procedure:
1. Write the appropriate
data (see following
table) to memory
location D607H.
2. Wait at least 75 µs.
3. Read location D606H.
4. Record the value.
1. Write the appropriate
data (see following
table) to memory
location D607H.
2. Enter "modify memory
MDS word 1#D607
<value from table>"
3. Enter "display memory
MDS word from
1#D606 to 1#D606"
4. Record the value.
The data should fall within
the range shown in the
Limits.
The data should fall within
the range shown in the
Limits.
Write Source
To Being
D607H Tested
Write Source
To Being
D607H Tested