Table 1. Initial IFR ATC-1400A Control Settings
Switch Initial Setting
RF LEVEL control -70 dBm
CW/NORM/OFF switch OFF
SUPPRESSOR ON/OFF switch OFF
SLS/ECHO ON/OFF switch OFF
XPDR PULSE WIDTH VAR/CAL switch CAL
FREQ STEP RATE control OFF
MAN/AUTO/MAN STEP switch MAN
XPDR DEV P3/CAL switch CAL
1.0µs/1.45µs switch 1.45 µs
XPDR DEV P2/CAL switch CAL
TO/TAC/TD switch TD
PRF/SQTR ON/OFF switch ON
F2/P2 F1/P1 switch F2/P2
XPDR MODE control A
DISPLAY SELECT control FREQ MHz
PRF/SQTR thumbwheels 45 Hz
DBL INTERR/INTERF PULSE thumbwheels 047.9 µs OFF
XPDR P2/P3 DEV thumbwheels 0.20 µs
FREQ/FUNCTION SELECT thumbwheels 1030 MHz XPDR
DELTA F thumbwheels 0.00 MHz OFF
XPDR PULSE WIDTH thumbwheels 0.00 µs
SLS/ECHO thumbwheels +0 dB
DECODER (at rear of unit) NARROW
NOTE: If unit is cold, provide a 5-minute warmup period. Adjust the FREQ and DELTA F thumbwheels
until the FREQ DISPLAY indicates 1030.00 MHz.
Initial IFR S-1403 Control Settings
Menu Sub-Menu/Field Initial Settings
Sequence S01 UF = 5
ADD = 25252525
S02 thru S16: OFF
Control Menu 1 Func: 1 ATC (ATCRBS)
RF Lvl: +0.0