User Instructions

SECURITY NOTATION SPEC
NO.
IT4061400-907
SEE PAGE INDEX
FOR THIS SHEET
REV LETTER
CAGE
CODE
58960
REV LTR
SEE THE TITLE PAGE FOR PROPRIETARY AND DATA RIGHTS NOTATIONS.
REV TEST SPECIFICATION PROCEDURE SPECIFICATION
LTR NO. OPR LIMITS C TEST DESCRIPTION SWITCH POS C WORK STEPS MFG LIMITS
AW/CRITICAL NOTATION
SUPPLEMENTS
A
-6
SECURITY NOTATION PAGE
15101-000 (REV 970213 BCAS ASF5900/ENG_SPEC.DOT) (REV 07/18/2000 -OFC97-DATA SERVICES) HONEYWELL INTERNATIONAL INC.
ENGINEERING
SPECIFICATION
A3.1 N/A Enter "SCP MDS" N/A
Enter "load verify MDS
IT30P.RA"
Enter "modify registers
MDS E0 80E"
H Enter "modify registers
MDS P 109"
Enter "Set discretes MDS
to 1FA"
Enter "run MDS"
NOTE: EEPROM is only
8 bits wide, instead of 16.
If 16 bits of data are
specified, only the least
significant 8 bits are used.
Thus, FE34H is the same
as 34H.
Program will take several
minutes to complete.
Front panel LEDs shall
flash in a repetitive
pattern while the program
is executing. When the
program is complete all
six LEDs shall be
illuminated.
Write the EEPROM
address (OOH thru FFH)
to each location in
EEPROM (8OOOH thru
9FFFH). Verify each
location.
Write the complement of
each EEPROM address
(FFH thru OOH) to each
location in EEPROM
(8OOOH thru 9FFFH).
Verify each location.
Write the value FFH to
each location in EEPROM
(8OOOH thru 9FFFH).