User Instructions

SECURITY NOTATION SPEC
NO.
IT4061400-907
SEE PAGE INDEX
FOR THIS SHEET
REV LETTER
CAGE
CODE
58960
REV LTR
SEE THE TITLE PAGE FOR PROPRIETARY AND DATA RIGHTS NOTATIONS.
REV
LTR
AW/CRITICAL NOTATION
SUPPLEMENTS
A
-1
SECURITY NOTATION PAGE
15101-000 (REV 970213 BCAS ASF5900/ENG_SPEC.DOT) (REV 07/18/2000 -OFC97-DATA SERVICES) HONEYWELL INTERNATIONAL INC.
ENGINEERING
SPECIFICATION
APPENDIX A
ALTERNATIVE TEST PROCEDURE FOR PC EMULATION SYSTEM
A1. Notes on operation of the PC emulation system are as follows:
A1.1 All tests requiring the PC emulation system shall be performed while executing the SDP-185
monitor software. In the engineering environment, the monitor is invoked by executing the 'SCP
MDS' command file.
A1.2 All address and data information should be entered in Hex with a leading # for CACHE locations
and a leading 1# for local memory. See example in 3.4.3.
A1.3 Most emulation commands are invoked by pressing the softkeys. Only addresses, data, and 'MDS'
are typed using the standard typewriter keys. For example, to change the contents of location C000
(Hex) to the value AAAA (Hex), the following PC command would be entered:
modify memory MDS word 0/#C0/0/0/ to AAAA
In this example, the words (modify, memory, word, and to) are entered with single-keystroke
softkeys.
A2. Notes and a list of PC command files (Honeywell Part No. MT4061400-101, revision a) are as follows:
A2.1 The total execution time of this Integrated Test Procedure may be greatly reduced by using the PC
command files listed in paragraph 3.11.3. These command files automatically execute many
keystrokes found in certain tests and match statement-for-statement (excluding 'pause' statements)
the steps found in the IT work steps.
A2.2 After executing the 'SCP MDS' batch file (see paragraph 3.4), execute the command file by typing
the filename (using all caps) into the PC and pressing ENTER. Most command files pause to allow
the operator to record data. Press any key to resume command file execution.