FAN SWING TURBO MODE QUIET SLEEP TIMER OFF ON CANCEL CLOCK CANCEL OPERATION MANUAL Before using your air conditioner, please read this operating manual carefully and keep it for future reference. Part No.: R08019034086 OM-GS02-1009(0)-Acson OM-GS02-1009(0)-Acson Downloaded from www.Manualslib.
GS02 Remote Control Indication / Indication De Télécommande GS02 / GS02-Fernbedienungsanzeige / Indicazioni Telecomando GS02 / Indicación Del Mando A Distancia GS02 / Индикация пульта дистанционного управления GS02 / GS02 Uzaktan Kumanda Göstergeleri 1 2 6 FAN SWING 7 3 4 5 TURBO MODE 13 QUIET SLEEP 12 9 TIMER 11 OFF ON CANCEL CLOCK 8 CANCEL 10 i OM-GS02-1009(0)-Acson Downloaded from www.Manualslib.
HOW TO MOUNT ONTO THE WALL / COMMENT INSTALLER SUR LE MUR / ANBRINGEN DER FERNSTEUERUNG AN DER WAND / COME FISSARE L’ASTUCCIO DEL TELECOMANDO ALLA PARETE / MONTAJE SOBRE LA PARED / КАК УСТАНОВИТЬ НА СТЕНУ / DUVARA NASIL YERLEfiT‹R‹L‹R FAN SWING TURBO MODE QUIET SLEEP TIMER CANCEL CLOCK FAN SWING OFF ON CANCEL TURBO MODE QUIET SLEEP TIMER OFF ON CANCEL CLOCK CANCEL TO INSERT BATTERIES (AAA.R03) / INTRODUIRE LES PILES (AAA.R03) / EINSETZEN DER BATTERIEN (AAA.
REMOTE CONTROLLER LOSS PREVENTION WITH BALL CHAIN (OPTIONAL) Remote controller Screw Wall attachment screw Holder Ball chain 1. 2. 3. Installation Match the ring at the end of the ball chain with the screw hole on the back of the remote controller and secure it with the screw. Attach the holder and the ball chain as above at the position where signals from the remote controller can be received easily.
iv OM-GS02-1009(0)-Acson Downloaded from www.Manualslib.
OPERATING GUIDE 1. 2. 3. 4. 5. 6. Transmission source • The source where the signal will be transmitted. Signal transmission indication • Blink to confirm that the last setting has been transmitted to the unit. “ON/OFF” Button • Press once to start the air conditioner unit. • Press again to stop the unit.
9. 10. 11. 12. 13. 2 OM-GS02-1009(0)-Acson Downloaded from www.Manualslib.com manuals search engine 2 1/4/10, 5:16 PM ENGLISH Original Instruction 8. • The Turbo function ( ) is unavailable for chilled water system and remote control with SWING MODE ( ) function. OFF timer setting • Press the OFF TIMER CANCEL button will activate the off timer function. • Set the desired off time by pressing the OFF TIMER CANCEL button continuously. • Press the CANCEL button to cancel the off timer setting.
FAULT DIAGNOSIS (For Inverter only) FAULT DIAGNOSIS BY REMOTE CONTROLLER The temperature display sections indicate corresponding codes. 1. When the ON TIMER CANCEL button or OFF TIMER CANCEL button is held down for 5 seconds, a “ ” indication flashes on the temperature display section. 00 FAN SWING TURBO MODE QUIET SLEEP TIMER OFF ON ON TIMER CANCEL CANCEL CLOCK CANCEL OFF TIMER CANCEL 2. Press the ON TIMER CANCEL button or OFF TIMER CANCEL button repeatedly until a continuous beep is produced.
MEANING OUTDOOR AIR THERMISTOR SHORT/OPEN PRESSURE SENSOR ERROR COMPRESSOR DISCHARGE PIPE THERMISTOR SHORT/OPEN/MISPLACED SUCTION PIPE THERMISTOR SHORT/OPEN OUTDOOR HEAT EXCHANGER THERMISTOR SHORT/OPEN SUBCOOLING HEAT EXCHANGER THERMISTOR SHORT/OPEN LIQUID PIPE THERMISTOR SHORT/OPEN GAS PIPE THERMISTOR SHORT/OPEN INVERTER OUTDOOR PCB ERROR OUTDOOR CONTROL BOX OVERHEAT HEAT SINK OVERHEAT IPM ERROR/IGBT ERROR INVERTER COMPRESSOR OVERCURRENT COMPRESSOR OVERCURRENT PREVENTION COMMUNICATION ERROR (OUTDOOR CONTRO
• In the event that there is any conflict in the interpretation of this manual and any translation of the same in any language, the English version of this manual shall prevail. • The manufacturer reserves the right to revise any of the specification and design contain herein at any time without prior notification. OYL MANUFACTURING COMPANY SDN. BHD. LOT 60334, PERSIARAN BUKIT RAHMAN PUTRA 3, TAMAN PERINDUSTRIAN BUKIT RAHMAN PUTRA, 47000 SUNGAI BULOH, SELANGOR DARUL EHSAN, MALAYSIA.