Specifications

R-410A-7
HORIZONTAL DUCTED CONDENSING UNIT A5HDC-AR SERIES - R-410A
WALL MOUNTED A5WM-G SERIES - R-410A
CEILING CONCEALED A5CC-C SERIES - R-410A
CEILING CASSETTE A5CK-A SERIES - R-410A
A5WM20GR A5WM25GR
A5HDC20AR A5HDC25AR
Btu/h 18300 24300
W 5363 7122
Btu/h 18500 23500
W 5442 6887
COOLING W 2297 2930
HEATING W 2067 2720
W/W 2.33 2.43
W/W 2.63 2.53
V/Ph/Hz
cfm / L/s 490 / 232 630 / 298
dBA 43 / 40 / 35 49 / 44 / 42
HEIGHT mm/in
WIDTH mm/in
DEPTH mm/in
kg
A5CC20CR A5CC25CR
A5HDC20AR A5HDC25AR
Btu/h 18300 24300
W 5360 7120
Btu/h 18500 23500
W 5420 6890
COOLING W 2350 2970
HEATING W 2120 2760
W/W 2.35 2.45
W/W 2.64 2.55
V/Ph/Hz
l/s / CFM 330 / 700 345 / 730
l/s / CFM 321 / 680 340 / 720
l/s / CFM 293 / 620 274 / 580
EXTERNAL STATIC PRESSURE (H/M/L) Pa (in.wg.) 64 / 58 / 34 (0.26 / 0.24 / 0.14) 55 / 39 / 29 (0.22 / 0.16 / 0.12)
dBA 38 / 36 / 34 40 / 39 / 36
HEIGHT mm/in 261 / 10.28 261 / 10.28
WIDTH mm/in 1065 / 41.93 1200 / 47.24
DEPTH mm/in 411 / 16.18 411 / 16.18
kg 22 25
EER/COP CALCULATION IS BASED ON EFFECTIVE POWER INPUT AS PER ISO 5151.
A5CK20AR A5CK25AR
A5HDC20AR A5HDC25AR
Btu/h 18700 24500
W 5481 7180
Btu/h 18800 23800
W 5510 6975
COOLING W 2336 2949
HEATING W 2106 2739
W/W 2.35 2.43
W/W 2.62 2.55
V/Ph/Hz
cfm / L/s 770 / 363 810 / 382
dBA 42 / 39 / 37 45 / 42 / 40
HEIGHT mm/in
WIDTH mm/in
DEPTH mm/in
kg 31 + 4 32 + 4
AIR FLOW
HIGH
MEDIUM
LOW
UNIT DIMENSION
( ) - WITH PANEL
SOUND PRESSURE LEVEL (H/M/L)
HEATPUMP MODEL
INDOOR UNIT
OUTDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT
POWER
POWER SOURCE
820 (930) / 32.2 (36.6)
820 (930) / 32.2 (36.6)
50 Hz
EER
COP
220 - 240 / 1 / 50
335 (363) / 13.2 (14.3)
AIR FLOW
INDOOR
UNIT
WEIGHT (UNIT + PANEL)
220 - 240 / 1 / 50
50 Hz
EER
COP
NOMINAL TOTAL INPUT
POWER
POWER SOURCE
HEATPUMP MODEL
OUTDOOR UNIT
INDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
INDOOR
UNIT
WEIGHT
SOUND PRESSURE LEVEL (H/M/L)
UNIT DIMENSION
HEATPUMP MODEL
INDOOR UNIT
OUTDOOR UNIT
NOMINAL COOLING CAPACITY
222 / 8.7
NOMINAL HEATING CAPACITY
50 Hz
NOMINAL TOTAL INPUT
POWER
EER
COP
16 / 35.27
POWER SOURCE 220 - 240 / 1 / 50
INDOOR
UNIT
AIR FLOW
SOUND PRESSURE LEVEL (H/M/L)
UNIT DIMENSION
WEIGHT
304 / 12.0
1062 / 41.8
A5HDC20AR A5HDC25AR
dBA 46 47
mm/in
mm/in
mm/in
kg 72 81
mm/in 6.35 / 1/4 6.35 / 1/4
mm/in 12.7 / 1/2 15.88 / 5/8
SOUND PRESSURE LEVEL
LIQUID
GAS
PIPE
CONNECTION
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
UNIT WEIGHT
TYPE
SIZE
OUTDOOR UNIT
1240 / 48.8
586 / 23.1
436 / 17.2
FLARE VALVE
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) I) FOR A5WM, SOUND PRESSURE LEVELS ARE MEASSURED IN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELOW THE UNIT.
II) FOR A5CC, SOUND PRESSURE LEVELS ARE MEASSURED IN ANECHOIC CHAMBER, ACCORDING TO JIS B 8616 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BELOW THE CENTER OF THE UNIT.
TESTED WITH 2m DUCT LENGTH AT THE AIR DISCHARGE OUTLET AND 1m DUCT LENGTH AT THE AIR RETURN INLET.
III) FOR A5CK, SOUND PRESSURE LEVEL ARE MEASSURED IN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FASCIA.