Specifications

R-410A-1
WALL MOUNTED A5WM-G SERIES - R-410A
WALL MOUNTED A5WM-G SERIES - R-410A
A5WM07GR A5WM09GR
A5WM10GR
A5WM15GR
A5LC07CR A5LC10CR
A5LC10CR
A5LC15CR
Btu/h
7500
9000
9500
12000
W
2200
2640
2780
3520
Btu/h
7500
9000
9500
12000
W
2200
2640
2780
3520
COOLING W
680 860
910
1230
HEATING W
550 745
770
1080
W/W
3.24 3.07
3.05
2.86
W/W
4.00 3.54
3.61
3.26
A5WM07G A5WM09G
A5WM10G
A5WM15G
A5LC07C A5LC10C
A5LC10C
A5LC15C
Btu/h
7500 9000
9500
12000
W
2200 2640
2780
3520
W
620 860
910
1230
W/W
3.55 3.07
3.05
2.86
V/Ph/Hz
HIGH l/s / cfm
142 / 300
163 / 345
MEDIUM l/s / cfm 118 / 250 135 / 285
LOW l/s / cfm
94 / 200
104 / 220
dBA
39 / 34 / 28
42 / 36 / 29
HEIGHT mm/in
WIDTH mm/in
DEPTH mm/in
kg/lb
dBA
44 46
46
49
HEIGHT mm/in
495/19.5
540/21.3
WIDTH mm/in
600/23.6
700/27.6
DEPTH mm/in
245/9.7
250/9.8
kg/lb
26/57.32 33/72.75
LIQUID mm/in
GAS mm/in
9.52 / 3/8
12.70 / 1/2
260 / 10.2
899 / 35.4
198 / 7.8
220-240/1/50
6.35 / 1/4
9.52 / 3/8
10/22.05
6.35 / 1/4
32/70.55
FLARE VALVE
540/21.3
700/27.6
250/9.8
12/26.46
260 / 10.2
799 / 31.5
198 / 7.8
FLARE VALVE
130 / 275
106 / 225
83 / 175
40 / 35 / 29
HEATPUMP MODEL
OUTDOOR UNIT
INDOOR UNIT
220-240/1/50
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL CAPACITY
50 Hz
NOMINAL TOTAL INPUT POWER
EER
SOUND PRESSURE LEVEL (H/M/L)
OUTDOOR UNIT
UNIT WEIGHT
SOUND PRESSURE LEVEL
UNIT WEIGHT
PIPE CONNECTION
TYPE
SIZE
UNIT DIMENSION
INDOOR UNIT
UNIT DIMENSION
AIR FLOW
COP
COOLING ONLY MODEL
INDOOR UNIT
OUTDOOR UNIT
POWER SOURCE
50 Hz
NOMINAL TOTAL INPUT POWER
EER
A5WM20GR A5WM25GR
A5LC20CR A5LC25CR
Btu/h
17850 <18000> 20350 <22500>
W
5230 <5280> 5960 <6590>
Btu/h
18000 <18500> 22000 <23000>
W
5280 <5420> 6448 <6740>
COOLING W 1630 <1663> 1860 <2195>
HEATING W 1546 <1630> 1870 <2106>
W/W 3.21 <3.17> 3.21 <3.00>
W/W 3.42 <3.33> 3.45 <3.20>
A5WM20G A5WM25G
A5LC20C A5LC25C
Btu/h
17850 <18000> 20350 <22500>
W
5230 <5280> 5960 <6590>
W 1630 <1663> 1860 <2195>
W/W 3.21 <3.17> 3.21 <3.00>
V/Ph/Hz
HIGH l/s / cfm 231 / 490 397 / 630
MEDIUM l/s / cfm 193 / 410 231 / 490
LOW l/s / cfm 160 / 340 208 / 440
dBA 43 / 40 / 35 49 / 44 / 42
HEIGHT mm/in
WIDTH mm/in
DEPTH mm/in
kg/lb
dBA
HEIGHT mm/in
654 / 25.7
756 / 29.8
WIDTH mm/in
855 / 33.7
855 / 33.7
DEPTH mm/in
328 / 12.9 328 / 12.9
kg/lb
59 / 130.1 62 / 136.7
LIQUID mm/in
GAS mm/in
12.70 / 1/2 15.88 / 5/8
15.88 / 5/8
756 / 29.8
855 / 33.7
328 / 12.9
68 / 149.9
17 / 37.48
54
FLARE VALVE
9.52 / 3/8
49 / 47 / 45
360 / 14.2
1200 / 47.2
200 / 7.9
316 / 670
297 / 630
236 / 500
220-240/1/50 <380-415/3/50>
26000 <26000>
7620 <7620>
2560 <2631>
2.98 <2.90>
2.98 <2.90>
3.12 <3.32>
A5WM311
A5LC28C
26000 <26000>
7620 <7620>
2560 <2631>
2442 <2294>
A5WM301R
A5LC28CR
26000 <26000>
7620 <7620>
OUTDOOR UNIT
SOUND PRESSURE LEVEL 52
UNIT DIMENSION
UNIT WEIGHT
PIPE CONNECTION
SIZE
6.35 / 1/4
TYPE
FLARE VALVE
16 / 35.27
UNIT DIMENSION
304 / 12.0
1062 / 41.8
222 / 8.7
INDOOR UNIT
AIR FLOW
SOUND PRESSURE LEVEL (H/M/L)
UNIT WEIGHT
50 Hz
NOMINAL TOTAL INPUT POWER - 1Ø <3Ø>
EER - 1Ø <3Ø>
POWER SOURCE - 1Ø <3Ø>
COOLING ONLY MODEL
INDOOR UNIT
OUTDOOR UNIT
NOMINAL CAPACITY - 1Ø <3Ø>
NOMINAL HEATING CAPACITY - 1Ø <3Ø>
50 Hz
NOMINAL TOTAL INPUT POWER
- 1Ø <3Ø>
EER - 1Ø <3Ø>
COP - 1Ø <3Ø>
HEATPUMP MODEL
INDOOR UNIT
OUTDOOR UNIT
NOMINAL COOLING CAPACITY - 1Ø <3Ø>
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) I) FOR A5WM 25G AND BELOW, SOUND PRESSURE LEVELS ARE MEASSURED IN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m
IN FRONT AND 0.8m BELOW THE UNIT.
II) FOR A5WM 311, SOUND PRESSURE LEVELS ARE MEASSURED IN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m
IN FRONT AND 1m BELOW THE UNIT.