Specifications
INTELLIGENT
CONTROL SERIES
28
S - NIM for Timer Switchover Control
Main
Board
Control
Panel
S-NIM
Main
Board
S-NIM
Master Unit Slave Unit
Typical connection
structure for S-NIM
• S-NIM controller
• Communication Bus
• Warehouse
• Laboratory
• Railway Switching Center
S-NIM
Built on the NIM configuration, S-NIM serves to enhance the abilities and extend the
operating lifetime of existing air conditioning units in harsh and demanding environment.
S-NIM works in a master & slave system, operating at alternate sequence of preset hours.
Whenever the operating unit is at fault, the standby unit will automatically takes over.
Features
• Auto restart feature with last state settings.
• 2 air conditioning units in a master & slave system, operating at alternate sequence of
preset time (3/4/5/7/9/11/12 hours).
• System controlled by a single Netware 3 or SLM3 wired controller.
• When the operating unit is at fault, the standby unit automatically takes over.
•
Error indication via error code displayed on LCD panel. (only is using Netware 3 control panel)
• During system OFF mode, running timer will stop. It resumes when changing to ON mode.
• Preset operation hours can be set via DIP Switch.
* The air conditioning unit connected to the wired controller is always the master unit.
The S-NIM system consists of
• Main Board controller
• Display control panel
S-NIM controller application
• Server Room
• Telecommunication Tower
• Livestock Breeding Farm
• Room with Critical
Electronics Equipments
NIM-Tele For Telephone Control
Benefits
• More convenience
• Simple to use with voice guided instruction
The NIM-Tele system consists of
• Main board controller
• Display control panel
• NIM-Tele controller
• Telephone line
NIM-Tele is a new application for the NIM, which presents an alternative form of
control over air conditioner via the use fixed-line or mobile telephones from other
places or long distance.
NIM-Tele is designed for Dual-Tone Multi-Frequency (DTMF) telephone with 3 (row)
by 4 (column) keypad.
Features
• LED for operation indication
• On/Off air conditioner capability
• Selection of air conditioner mode of operation
• Operating temperature setting between
16˚C and 30˚C or 60˚F and 86˚F
• Tele-control capability
• User acknowledgement with beep sound
• Password system to restrict access
• Password change feature and initial
password setting
• Control of NIM-Tele guided by voice instruction
• Improper operation protection
NIM-Tele
Main Board
Control
Panel
NIM-Tele
Main Board
NIM-Tele
or
Typical connection of NIM-Tele