R-410A / R-407C Air-Cooled Product System Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. For the most up-to-date product information, please go to www.acson-international.com. ©2008 Acson International AP - AOF - 08A www.acson-international.
About Acson International With products available in more than 55 countries spread across 7 continents around the world, Acson is truly international. Backed by an advanced research and development team, manufacturing facilities as well as highly-trained and extensive service network, Acson International has the key to provide ideal solution for any air-conditioning system.
PRODUCT LINE-UP Features Specification R-410A Specification R-407C Wall Mounted Single Split G Series Multi Split A Series Ceiling Cassette A & C Series Ceiling Convertible E Series Ceiling Convertible C & D Series Ceiling Concealed D Series Ceiling Concealed C Series Horizontal Ducted Condensing Unit A Series Ducted Split D & ER Series Air-Cooled Rooftop A Series Intelligent Control Series Pg.4 Pg.8 Pg.10 Pg.12 Pg.14 Pg.16 Pg.18 Pg.20 Pg.22 Pg.24 Pg.26 Pg.29 Pg.R-410A-1 – Pg.
WALL MOUNTED G SERIES INDOOR AIR QUALITY IMPROVEMENT 2: Negative Ion Generator (Standard) The Ion Generator releases a shower of negative ion to create a refreshing and cleaner environment. A5WM 07/09/10/15/20/25 G/GR A5WM 07/09/10/15/20/25 G/GR Cooling: 7500 Btu/h - 21000 Btu/h 2.20 kW - 6.16 kW Heating: 7500 Btu/h - 22000 Btu/h 2.20 kW - 6.
WALL MOUNTED G SERIES Turbo Mode Easy Serviceability Wall Mounted G series comes with a new design of air discharge housing whereby the fan blower can be easily accessed by just loosing up two screws on the unit. This new feature provides a flexible, faster and easier way to clean up the fan blower and ionizer. New Aesthetically Outlook A smooth front panel makes the cleaning process much easier for the user. These units blended easily into any interior decoration and design.
WALL MOUNTED MULTI SPLIT SYSTEMS Multi Split Schematic Comprehensive Product Range MSD Series: Double Compressor 2-Indoor Split System Acson offers a very comprehensive range of Multi-Split condensing units, right from System 2 (1 outdoor to 2 indoors) up to System 3 (1 outdoor to 3 indoors). In addition, each of the product range has various cooling / heating capacity combinations. COMP. A A COMP.
CEILING CASSETTE Wide Range Of Offerings 4 Way Air Discharge And Air Swing Acson Ceiling Casssette offers flexibility and choices for installation depending on the interior design requirements. The compact A5CK-C series fits perfectly into the standard ceiling board of 600mm x 600mm and thus offers easier installation. It comes with 4 way air discharge and air swing function to ensure better air distribution and circulation in the room.
CEILING CONVERTIBLE E SERIES Ceiling and Floor Installation Option Better Serviceability The A5CM is designed with the option to install either below the ceiling or mounted at low wall position to suit any interior design requirement. The washable filter can be easily access by just pulling down the intake grill. During servicing or repairing, only the bottom panel need to be remove in order to access.
CEILING CONVERTIBLE D SERIES Ceiling And Floor Installing Option** Auto Random Restart The unit is designed with possibility to be installed under the ceiling or sitting on the floor to suit any interior design requirements. When there is power failure occurs during operation, the unit will automatically restart as the last setting condition when the power is resumed. Option is provided to cancel this feature.
CEILING CONCEALED D SERIES Hide Away Operation Higher Level Of Protection Installed concealed above the ceiling, A5CC-D is designed to create a more comfortable and healtier indoor air climate, while remaining hide away. This allows user to enjoy conditioned air without sacrificing room space or interior design creativity. Each A5CC-D series is incorporated with an unique safety feature, i.e a float switch, to protect the unit from possible problems of condensate water over flow inside the unit.
CEILING CONCEALED C SERIES Microprocessor Controlled Duct Accessories (Optional) With the microprocessor controlling the operation, the A5CC model can offer more comfortable room conditions according to the needs of the user. In addition, its control algorithms can provide protection to components of the air conditioning unit against faulty. A set duct accessories specifically designed to fit and to suit the A5CC-C model is being created. Thus offers a one stop solution to installing the unit.
HORIZONTAL DUCTED CONDENSING UNIT Low Height & Compact Design Robust Unit The low height of 436 mm of the A5HDC can easily be fit into any concealed ceiling and covered by either false ceiling or ceiling board. Constructed with gauge galvanized steel and powder paint, the A5HDC is designed to resist the toughest climate and has better weather protection. This helps to established the AHDC series as a more robust unit. 436 mm or 17.
DUCTED SPLIT Better Air Distribution For Comfortable Living Sequential Controller For Models The conditioned air can be effectively distributed to the room through the ducting. * ADB 150 ER2 To ADB 600 ER4 * ADB 150D2 TO ADB 500D4 This is a multi purpose controller that provides the following features: Fresh Air For Healthier Living Fresh air can be introduced into the building through the design of fresh air intakes. This will improve the indoor air quality.
AIR-COOLED ROOFTOP PACKAGED Flexibility In Supplying Comfort Air ICE ICE CR AM CRE EA M One Complete Set Concept A4RT 60/80/100/120/150/200 A/AR The A4RT is a complete packaged unit by itself. No additional refrigeration work is require of site. This will expedited installation time and minimise installation labor involve. The refrigerant is optimally factory charge to ensure cleaner and more efficient operation.
INTELLIGENT CONTROL SERIES Network Control NIM Main board controllers and display control panel Network Interface Module (NIM) is a networking system which enables communication among Acson air conditioners. With the Network Interface Module (NIM), all your air conditioning systems can be controlled with just a single controller giving you benefits: BENEFITS Fig: NIM • More convenience.
INTELLIGENT CONTROL SERIES S - NIM for Timer Switchover Control Built on the NIM configuration, S-NIM serves to enhance the abilities and extend the operating lifetime of existing air conditioning units in harsh and demanding environment. S-NIM works in a master & slave system, operating at alternate sequence of preset hours. Whenever the operating unit is at fault, the standby unit will automatically takes over. Features • Auto restart feature with last state settings.
HEAT EXCHANGER HRB 30/50/80/100/150/200 A Capacity: 300m3/h - 2000 m3/h 177 cfm - 1177 cfm HRB 30/50/80/100/150/200 A This Heat Exchanger (HRB) is able to introduce fresh air into the confined room or area and at the same time, it is able to reduce power consumption. The HRB are available in 6 sizes, namely 300m3/h, 500m3/h, 800m3/h, 1000m3/h, 1500m3/h and 2000m3/h. 4.2ºC Discharging The Dirty Air 2-Way Air Exchange The HRB is capable to provide 2-way air exchange.
WALL MOUNTED A5WM-G SERIES - R-410A HEATPUMP MODEL INDOOR UNIT A5WM07GR A5WM09GR A5WM10GR A5WM15GR OUTDOOR UNIT A5LC07CR A5LC10CR A5LC10CR A5LC15CR Btu/h 7500 9000 9500 12000 W 2200 2640 2780 3520 Btu/h 7500 9000 9500 12000 NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY W 2200 2640 2780 3520 COOLING W 680 860 910 1230 HEATING W 550 745 770 1080 EER W/W 3.24 3.07 3.05 2.86 COP W/W 4.00 3.54 3.61 3.
CEILING CASSETTE A5CK-A SERIES - R-410A HEATPUMP MODEL INDOOR UNIT A5CK20AR A5CK25AR OUTDOOR UNIT A5LC20CR A5LC25CR A5LC28CR 18500 <18500> 20000 <22860> 28000 <27000> Btu/h NOMINAL COOLING CAPACITY - 1Ø <3Ø> NOMINAL HEATING CAPACITY - 1Ø <3Ø> 50 Hz 5860 <6700> 8210 <7910> 21500 <23200> 28000 <27000> 5420 <5420> 6300 <6800> 8210 <7910> W 1703 <1778> 2003 <2260> 2680 <2729> HEATING W 1563 <1573> 2033 <2153> 2150 <2381> EER - 1Ø <3Ø> W/W 3.18 <3.05> 2.93 <2.96> 3.06 <2.
CEILING CASSETTE A5CK-C SERIES - R-410A INDOOR UNIT A5CK10CR A5CK15CR A5CK20CR HEATPUMP MODEL OUTDOOR UNIT A5LC10CR A5LC15CR A5LC20CR Btu/h 9500 12500 17500 <18000> W 2780 3660 5129 <5280> Btu/h 9500 11500 17500 <18500> W 2780 3370 5129 <5420> NOMINAL COOLING CAPACITY - 1Ø <3Ø> NOMINAL HEATING CAPACITY - 1Ø <3Ø> NOMINAL TOTAL INPUT POWER COOLING W 900 1300 1690 <1724> - 1Ø <3Ø> HEATING W 830 1020 1710 <1494> W/W 3.09 2.82 3.03 <3.
CEILING CONVERTIBLE A5CM-E SERIES - R- 410A HEATPUMP MODEL INDOOR UNIT A5CM15ER A5CM20ER A5CM25ER OUTDOOR UNIT A5LC15CR A5LC20CR A5LC25CR A5LC28CR 12900 17500 <18100> 20000 <22860> 27000 <26000> NOMINAL COOLING CAPACITY - 1Ø <3Ø> NOMINAL HEATING CAPACITY - 1Ø <3Ø> Btu/h A5CM28ER W 3780 5130 <5300> 5860 <6700> 7900 <7620> Btu/h 11800 18500 <18770> 22000 <23200> 27500 <26500> W 3460 5420 <5500> 6450 <6800> 8050 <7770> COOLING W 1280 1723 <1757> 1973 <2231> 2754 <2715> HEA
CEILING CONCEALED A5CC-D SERIES - R-410A HEATPUMP MODEL INDOOR UNIT A5CC30DR OUTDOOR UNIT A5LC28CR A5LC35CR A5LC40CR 26500 <28000> 33000 <33000> 38000 <38000> Btu/h NOMINAL COOLING CAPACITY - 1Ø <3Ø> NOMINAL HEATING CAPACITY - 1Ø <3Ø> 50 Hz 9670 <9670> 11140 <11140> 34000 <34000> 39000 <39000> 7770 <8210> 9960 <9960> 11430 <11430> W 2690 <3046> 3324 <3253> 4207 <3872> HEATING W 2332 <2698> 3184 <2973> 3683 <3494> EER - 1Ø <3Ø> W/W 3.22 <2.96> 3.19 <3.27> 2.85 <3.
CEILING CONCEALED A5CC-C SERIES - R-410A HEATPUMP MODEL INDOOR UNIT A5CC10CR A5CC15CR A5CC20CR OUTDOOR UNIT A5LC10CR A5LC15CR A5LC20CR A5LC25CR Btu/h 9500 12500 18000 <18000> 21000 <22860> NOMINAL COOLING CAPACITY - 1Ø <3Ø> NOMINAL HEATING CAPACITY - 1Ø <3Ø> A5CC25CR W 2780 3660 5280 <5280> 6155 <6700> Btu/h 9500 12000 18500 <18500> 22000 <23200> W 2780 3520 5420 <5420> 6450 <6800> COOLING W 961 1297 1757 <1791> 2003 <2274> HEATING W 813 1147 1597 <1561> 1953 <2167
HORIZONTAL DUCTED CONDENSING UNIT A5HDC-AR SERIES - R-410A OUTDOOR UNIT A5HDC20AR SOUND PRESSURE LEVEL UNIT DIMENSION dBA mm/in 436 / 17.2 WIDTH mm/in 1240 / 48.8 DEPTH mm/in 586 / 23.1 kg 72 TYPE SIZE 47 HEIGHT UNIT WEIGHT PIPE CONNECTION A5HDC25AR 46 81 FLARE VALVE LIQUID mm/in 6.35 / 1/4 6.35 / 1/4 GAS mm/in 12.7 / 1/2 15.
MULTI-SPLIT A4MSD-A SERIES WITH WALL MOUNTED - R-407C HEATPUMP MODEL OUTDOOR UNIT A4MSD 1010AR INDOOR UNIT 2 x AWM 10GR AWM 10GR AWM 15GR 2 x AWM 15GR Btu/h 2 x 9000 9000 10500 2 x 10500 W 2 x 2640 2640 3080 2 x 3080 Btu/h 2 x 9000 9000 11500 2 x 11500 NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY W 2 x 2640 2640 3370 2 x 3370 ONE UNIT RUNNING W 996 996 1470 1470 TWO UNITS RUNNING W 1916 NOMINAL POWER INPUTHEATING ONE UNIT RUNNING W 994 TWO UNITS RUNNING W 17
CEILING CONCEALED ACC-D SERIES - R-407C HEATPUMP MODEL NOMINAL HEATING CAPACITY 100000 21980 29310 Btu/h 84000 110000 24620 32240 W 7827 11040 HEATING W 7827 9279 EER W/W 3.12 2.80 COP W/W 3.49 3.70 ACC75D ACC100D INDOOR UNIT NOMINAL TOTAL INPUT POWER EER 100000 W 21980 29310 W 7827 11040 W/W 3.12 2.
DUCTED SPLIT ADB-D SERIES - R-407C INDOOR UNIT ADB125D ADB150D1 ADB150D2 ADB200D2 A4MC125D A4MC150D A4MC75D x 2 A4MC100D x 2 Btu/h 108000 145000 146000 182000 W 31653 42497 42790 53500 COOLING ONLY MODEL OUTDOOR UNIT NOMINAL CAPACITY 50 Hz NOMINAL TOTAL INPUT POWER POWER SOURCE AIR FLOW HIGH INDOOR UNIT EXTERNAL STATIC PRESSURE SOUND PRESSURE LEVEL UNIT DIMENSION 16239 16424 21100 380~415 / 3 / 50 380~415 / 3 / 50 380~415 / 3 / 50 l/s / cfm 1770 / 3750 2124 / 4500 2124 / 4
DUCTED SPLIT ADB-ER SERIES - R-407C HEATPUMP MODEL INDOOR UNIT NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY 50 Hz NOMINAL TOTAL INPUT POWER INDOOR UNIT INDOOR UNIT Btu/h 73000 91000 W 21400 26670 Btu/h 81000 109000 W 23740 31950 W 8024 10610 HEATING W 8224 10610 V/Ph/Hz 400 / 3 / 50 HIGH L/s / CFM 1061.9 / 2250 1415.8 / 3000 MEDIUM L/s / CFM 972.2 / 2060 1321.5 / 2800 LOW L/s / CFM 731.5 / 1550 1227.1 / 2600 Pa/mmAq (105.9 / 10.8) / (93.2 / 9.5) / (64.7 / 6.
DUCTED SPLIT ADB-ER SERIES - R-407C INDOOR UNIT HEATPUMP MODEL OUTDOOR UNIT Btu/h NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY 50 Hz NOMINAL TOTAL INPUT POWER INDOOR UNIT ADB250ER2 ADB300ER2 ADB300ER3 A4MC125ER x 2 A4MC150ER x 2 A4MC100ER x 3 182000 216000 290000 273000 ADB350ER3 A4MC125ER x 2 A4MC100ER 307000 W 53340 63310 84990 90010 89980 Btu/h 218000 248000 300000 327000 357000 W 63890 72680 87920 95840 104630 COOLING W 21030 24730 32998 31450 35020 HEAT
AIR-COOLED ROOFTOP A4RT-A SERIES - R-407C HEATPUMP MODEL A4RT60AR A4RT80AR A4RT100AR A4RT120AR A4RT150AR Btu/h 57000 72000 88000 100000 149000 W 16705 21101 25790 29307 43668 Btu/h 69000 77000 102000 122000 160000 W 20222 22566 29893 35755 46891 NOMINAL TOTAL INPUT COOLING W 6860 8410 10820 12840 16570 POWER HEATING W 6600 7540 9810 11490 15710 A4RT60A A4RT80A Btu/h 59000 72000 W 17291 W 5890 NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY 50 Hz CO