Specifications
ADT60/AET60 Reference Manual version 1.5 November 2005
BAUD RATE Selects the baud rate (bps) of the serial interface between reader and host system. The
default hardware baud rate is 9600 bps. (Baud rate changes are only valid on RS232
reader).
BAUD RATE Serial baud rate (bps)
12
H
9600
11
H
19200
10
H
38400
03
H
14400
02
H
28800
01
H
57600
00
H
115200
Response data format
No response data
The new protocol becomes effective by the completion of the SET_PROTOCOL command, immediately
after the BioCARDKey/BioSIMKey has sent out the response string to the SET_PROTOCOL
command.
8.1.3 SELECT_CARD_TYPE
This command sets the required card type. The firmware in the BioCARDKey/BioSIMKey adjusts the
communication protocol between reader and the inserted card according to the selected card type.
Command format
Instruction Code Data length Data
TYPE
02
H
01
H
TYPE See Appendix A for the value to be specified in this command for a particular card to be used.
Response data format
No response data
Advanced Card Systems Ltd. Page 17 of 25