8.1.6. PC_to_RDR_SetParameters
Sets slot parameters.
Offset Field Size Value Description
0
bMessageType
1 61h -
1
dwLength
4 - Size of extra bytes of this message
5
bSlot
1 00-05h
Identifies the slot number for this
command
6
bSeq
1 00-FFh Sequence number for command
7
bProtocolNum
1
00h,
01h
Specifies what protocol data structure
follows.
00h = Structure for protocol T=0
01h = Structure for protocol T=1
The following values are reserved for
future use:
80h = Structure for 2-wire protocol
81h = Structure for 3-wire protocol
82h = Structure for I2C protocol
8
abRFU
2 -
Reserved for future use
10
abProtocolDataStructure
Byte
array
- Protocol Data Structure
The response to this message is the RDR_to_PC_Parameters message.
Protocol Data Structure for Protocol T=0 (dwLength=00000005h)
Offset Field Size Value Description
10
bmFindexDindex
1 -
B7-4 FI Index into the Table 7 in
ISO/IEC 7816-3:1997 selecting a clock
rate conversion factor
B3-0 DI - Index into the Table 8 in
ISO/IEC 7816-3:1997 selecting a baud
rate conversion factor
11
bmTCCKST0
1 -
B0 0b, B7-2 000000b
B1 Convention used (b1=0 for direct,
b1=1 for inverse) Note: The CCID
ignores this bit.
12
bGuardTimeT0
1 00-FFh
Extra guard time between two
characters. Add 0 to 254etu to the
normal guard time of 12etu. FFh is the
same as 00h.
13
bWaitingIntegerT0
1 00-FFh WI for T=0 used to define WWT