Appendix B: Response Status Codes
The following table summarizes the possible status code bytes SW1, SW2 returned by the ACR30:
SW1 SW2 Status
90 00 OK – command successfully executed
90 01 OK – using T=1 protocol (only in response to the RESET command)
90 10 OK – synchronous protocol is used (only in response to the RESET
command). The exact card type should be selected by using the
SELECT_CARD_TYPE command.
60 01 No card type selected
60 02 No card in reader
60 03 Wrong card type specified
60 04 Card not powered up;
This status code is also returned in a response if the card was
temporarily removed during a card access.
60 05 Invalid Instruction Code
60 20 Card failure
60 22 Short circuit at card connector
62 01 Secret code verify failed
67 01 Command incompatible with card type
67 02 Card address error
67 03 Data length error
67 04 Invalid length of response (with READ command)
67 05 Secret code locked
67 12 APDU command aborted (only MCU-based card using T=1 protocol);
the command abortion may be caused by a card internal failure.