Manual

AIV-HM76V1FL Series User Manual
28
Acrosser Technology Co., Ltd.
3.2.5. Power Sub System
Power Sub System.
Aptio Setup Utility - Copyright (C) 2012 American Megatrends, Inc.
Version 2.15.1226. Copyright (C) 2012 American Megatrends, Inc.
→←: Select Screen
↑↓: Select Item
Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save & Exit
ESC: Exit
Advanced
Model
Firmware Version
Power Board Type
Battery Voltage
Battery Low Monitor
Battery Low Delta
Remote Switch
Power On Delay (Sec.)
Soft-Off Delay (Sec.)
Shutdown Delay (Sec.)
Hard-Off Delay (Sec.)
HM76V1
V1.0
[In-Vehicle]
11.62 V
[Disabled]
[1.5 V]
[Disabled]
8
5
180
60
[Enabled]/[Disabled]
Battery Low Voltage
Monitor Function
Power Board Type
Options Description
In-Vehicle / Embedded Displays the power board type.
Battery Voltage
Detects and display the battery voltage level.
Note: The following items apper only if the “Power Board Type” is [In-Vehicle].
Battery Low Monitor
Options Description
Enabled / Disabled Enables or disables the monitor function of low battery voltage.
Battery Low Delta
Options Description
0.5 / 1.0 / 1.5 / 2.0 / 2.5 / 3.0 Sets the battery delta level. Once the battery voltage drops below
this level, the battery will be detected as battery low.
Remote Switch
Options Description
Enabled / Disabled Enables or disables the function of remote switch.