User`s manual

70
SPECIFICATIONS
Clock Accuracy Monthly accuracy ± 15 sec. (at ordinary temperatures)
Calendar Year up to 2099. Automatically adjusted to leap years, 31-day
months and months with 30 or fewer days, and the days of the
week.
Printing System Dot matrix
Power Failure
Compensation
Three years of cumulative power failure hours after the date of
shipment.
Print at Power Failure Optional Ni-Cd battery, 200 print registrations or 24 hours
Acroprint part number 58-0108-000
Lithium Battery Toshiba part number ER3VT2
Time Program External time signal
Built-in buzzer
Printing an I-Mark™ (*)
Connection of External
Signal
Connection with optional functions:
External Alarm device : No voltage signal output.
Master Clock device : 6 to 32 V signal input.
Operating Environment Temperature: -5° to +45°C, +25° to +113°F
Humidity: 20 to 80%, no condensation
The unit operates normally at temperatures of 5°C (25°F) or
below, but the print density and reaction of the liquid crystal
display are inferior to those at normal temperature operation.
Dimensions 6.14" (w) x 7.13" (h) x 6.97" (d)
156 (w) x 181 (h) x 177 (d) mm
Weight Approx. 4.0 lbs. (1.8 kg)
Rating 120 VAC 50/60 Hz 0.4 A
220-240 VAC 50/60 Hz 0.2 A