User`s guide

74 Copyright © Acronis, Inc., 2000-2010
This option is not available when operating under the bootable media.
The option defines whether the agent(s) operating on the managed machine have to send the log
events of the recovery operations to the specified Simple Network Management Protocol (SNMP)
managers. You can choose the types of events to be sent.
Acronis Backup & Recovery 10 provides the following Simple Network Management Protocol (SNMP)
objects to SNMP management applications:
1.3.6.1.4.1.24769.100.200.1.0 - string identifying the type of event (Information, Warning, Error)
1.3.6.1.4.1.24769.100.200.2.0 - string containing the text description of the event (it looks identical
to messages published by Acronis Backup & Recovery 10 in its log).
The preset is: Use the setting set in the Machine options.
To select whether to send the recovery operations events to the SNMP managers:
Choose one of the following:
Use the setting set in the Machine options to use the setting specified for the machine. For
more information refer to Machine options (p. 45).
Send SNMP notifications individually for recovery operation eventsto send the events of the
recovery operations to the specified SNMP managers.
Types of events to sendchoose the types of events to be sent: All events, Errors and
warnings, or Errors only.
Server name/IPtype the name or IP address of the host running the SNMP management
application, the messages will be sent to.
Communitytype the name of SNMP community to which both the host running SNMP
management application and the sending machine belong. The typical community is "public".
Click Send test message to check if the settings are correct.
Do not send SNMP notificationsto disable sending the log events of the recovery operations to
SNMP managers.
Error handling
These options are effective for Windows and Linux operating systems and bootable media.
These options enable you to specify how to handle errors that might occur during recovery.
Do not show messages and dialogs while processing (silent mode)
The preset is: Disabled.
With the silent mode enabled, the program will automatically handle situations requiring user
interaction where possible. If an operation cannot continue without user interaction, it will fail.
Details of the operation, including errors, if any, can be found in the operation log.
Re-attempt, if an error occurs
The preset is: Enabled. Number of attempts: 5. Interval between attempts: 30 seconds.
When a recoverable error occurs, the program re-attempts to perform the unsuccessful operation.
You can set the time interval and the number of attempts. The attempts will be stopped as soon as
the operation succeeds OR the specified number of attempts is performed, depending on which
comes first.