User`s manual

I/O SERVER User’s Manual Industrial PC
__________________________________________________________________
________________________________________________________________________
Acromag, Inc. Tel:248-624-1541 Fax:248-624-9234 Email:solutions@acromag.com http://www.acromag.com
42
Operating Temperature: -30°C to +75°C
Relative Humidity: 5-95% Non-Condensing.
Storage Temperature: -40°C to 85°C.
Non-Isolated: Power and field commons have a direct electrical
connection.
Shock & Vibration Immunity: Surface mounted unit with all cables
attached except USB Ports 3 and 4
Sinusoidal Vibration: IEC 60068-2-6: 10-500 Hz, 5G, 2 Hours/axis
Random Vibration: IEC 60068-2-64: 10-500 Hz, 5G-rms, 2 Hours/axis
Operating Shock: IEC 60068-2-27:
30g, 11 ms half sine, 18 shocks at 6 orientations
50g, 3ms half sine, 18 shocks at 6 orientations
Safety Approvals: FCC Class A, CE Pending (EMC Directive
89/336/EEC), UL Pending (UL508-Seventeenth Edition, ISA
12.12.01:2000), cUL Pending (Canada StandardC22.2, No. 142-M1987 &
213-M1987).
Electromagnetic Interference Immunity (EMI): Inputs/outputs have
demonstrated resistance to inadvertent state changes with interference
from switching solenoids, commutator motors, and drill motors.
Electromagnetic Compatibility (EMC) -
Minimum Immunity per European Norm EN61000-6-2:2001
Electrostatic Discharge (ESD) Immunity: 4KV direct contact and 8KV
air-discharge to the enclosure port per IEC61000-4-2.
Radiated Field Immunity (RFI): 10V/M, 80 to 1000MHz AM and
900MHz keyed carrier, per IEC61000-4-3.
Electrical Fast Transient Immunity (EFT): 2KV to power, and 1KV to
signal I/O per IEC61000-4-4.
Conducted RF Immunity (CRFI): 10Vrms, 150KHz to 80MHz, per
IEC61000-4-6.
Surge Immunity: 0.5KV to power per IEC61000-4-5. By the standard,
this test is not applicable to DC power input ports intended to be
permanently connected to cables less than 10m in length. Further,
this test is not applicable to I/O ports that interface via cables whose
total length is less than 30m.
Emissions per European Norm EN61000-6-4:2001
Radiated Frequency Emissions: 30 to 1000MHz per CISPR11 Class A
WARNING: This is a Class A product. In a domestic environment, this
product may cause radio interference in which the user may be
required to take adequate measures.
ENVIRONMENTAL