4.2 TEST PROCEDURE
Spectrum Parameter
Setting
Attenuation
Auto
Detector
Peak/AV
Start Frequency
1000 MHz(Peak/AV)
Stop Frequency
10th carrier hamonic(Peak/AV)
RB / VB (emission in restricted
band)
PK=1MHz / 1MHz, AV=1 MHz /10 Hz
(Peak detector is for Both)
a. The measuring distance of at 3 m shall be used for measurements at frequency 0.009MHz up to
1GHz,and above 1GHz.
b. The EUT was placed on the top of a rotating table 0.8 meters (above 1GHz is 1.5 m) above the
ground at a 3 meter anechoic chamber test site. The table was rotated 360 degrees to determine
the position of the highest radiation.
c. The height of the equipment shall be 0.8 m(above 1GHz is 1.5 m); the height of the test antenna
shall vary between 1 m to 4 m. horizontal and vertical polarizations of the antenna are set to
make the measurement.
d. The initial step in collecting conducted emission data is a spectrum analyzer peak detector mode
pre-scanning the measurement frequency range. Significant peaks are then marked and then
QuasiPeak detector mode re-measured.
e. If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit, the
EUT shall be deemed to meet QP Limits and then no additional QP Mode measurement
performed.
f. For the actual test configuration, please refer to the related Item –EUT Test Photos.
Note:
Both horizontal and vertical antenna polarities were tested and performed pretest to three
orthogonal axis. The worst case emissions were reported
For fundamental frequency ,RBW>20dB BW ,VBW>RBW,PK detector for PK value, RMS detector
for AV value.