4. RADIATED EMISSION MEASUREMENT
4.1 LIMIT
In any 100 kHz bandwidth outside the operating frequency band. In case the emission fall within
the Restricted band specified on Part15.205(a)&209(a) limit in the table and according to ANSI
C63.10-2013 below has to be followed
LIMITS OF RADIATED EMISSION MEASUREMENT (0.009mhz - 1000mhz)
Frequencies
(MHz)
Field Strength
(micorvolts/meter)
Measurement Distance
(meters)
0.009~0.490
2400/F(KHz)
300
0.490~1.705
24000/F(KHz)
30
1.705~30.0
30
30
30~88
100
3
88~216
150
3
216~960
200
3
Above 960
500
3
LIMITS OF RADIATED EMISSION MEASUREMENT (1GHz-25 GHz)
FREQUENCY (MHz)
(dBuV/m) (at 3M)
PEAK
AVERAGE
Above 1000
74
54
LIMITS OF FIELD STRENGTH OF THE FUNDAMENTAL SIGNAL
FREQUENCY (MHz)
(dBuV/m) (at 3M)
PEAK
AVERAGE
2400-2483.5
114
94
Notes:
(1) The limit for radiated test was performed according to FCC PART 15C.
(2) The tighter limit applies at the band edges.