Safety Information

Page 14 of 33 Report No.:FCS202103006W01
Flux Compliance Service Laboratory
Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan
Tel: 769-27280901 Fax:769-27280901 http://www.fcs-lab.com
3.4 TEST RESULTS
Temperature:
25
Relative Humidity:
50%
Test Mode:
GFSK
Test Voltage:
DC 3.7V
Phase:
L
Result:
Pass
No.
Frequency
Reading
Correct
Result
Limit
Margin
Remark
(MHz)
(dBuV)
Factor(dB/m)
(dBuV/m)
(dBuV/m)
(dB)
1
0.1725
35.23
9.78
45.01
64.84
19.83
QP
2
0.1725
16.54
9.78
26.32
54.84
28.52
AVG
3
0.7125
34.88
9.89
44.77
56.00
11.23
QP
4
0.7125
25.94
9.89
35.83
46.00
10.17
AVG
5
1.4460
22.70
12.15
34.85
56.00
21.15
QP
6
1.4460
11.31
12.15
23.46
46.00
22.54
AVG
7
1.9995
21.61
14.93
36.54
56.00
19.46
QP
8
1.9995
11.28
14.93
26.21
46.00
19.79
AVG
9
3.9750
20.64
18.24
38.88
56.00
17.12
QP
10
3.9750
9.95
18.24
28.19
46.00
17.81
AVG
11
16.3005
25.92
20.13
46.05
60.00
13.95
QP
12
16.3005
9.07
20.13
29.20
50.00
20.80
AVG