Master 
Controller Wire 
Searchlight 
Cable Wire 
Power Source 
Lead 
Function 
Orange 
+12 VDC or +24 
VDC** 
Power 
Blue 
Ground 
Ground 
Yellow 
Yellow 
Lamp Power 
Green 
Green 
Lamp Ground 
Red 
Red 
Up 
White 
White 
Down 
Black 
Black 
Right 
Brown 
Brown 
Left 
Table 1 
  WARNING: This wire MUST be fused with a 15 amp fuse in the 
Master Controller's in-line fuse-holder. 
Wiring to Searchlight 
The RCL-100 Searchlight is supplied  with a 15 foot integral wire 
harness. This wire harness is cut to this length specifically to allow for 
a voltage  drop.  Shortening the harness  will  decrease the  life  of the 
bulbs. Any extra length of wire harness should be loosely coiled in a 
convenient place.  For  best  performance, the  controller  should  be 
attached to the end of the 15' Searchlight wire harness. If you must 
lengthen  the  wire  harness,  use  heavy  duty  wire  to  minimize the 
voltage  drop.  This  is  especially  important  for  the  YELLOW  lamp 
power and GREEN lamp ground wires. 
Following the wiring scheme shown in Table 1 use the supplied butt 
connectors to connect the Master Controller to the Searchlight. 
Wiring to Point Pad™ 
The  RG-59  Coax  cable  is  supplied  without  the  “F”  connectors 
attached for ease of routing. After the coax has been routed, strip the 
insulation  and  crimp  the  “F”  connectors  in  place.  Screw  the  “F” 
connectors to the Master Controller and the Point Pad™.  
Wiring to Power Supply 
The  power  source  must  be  a  fused  12  VDC,  10-amp  supply  or  24 
VDC, 5-amp supply. Following the wiring scheme in Table 1, use the 
supplied  butt  connectors  to  connect  the  Master  Controller  to  the 
Power Source. Refer to Table 2 for proper wire size for connection of 
the input power lines. 