Specifications

FEATURES/DESCRIPTION
RANGE COMPATIBILITY MODEL CAT. NO.LENGTH/SIZE
42
Accessories
SENSORS: Electrical – AC Voltage
1
120 VAC, 60 HZ SINGLE PHASE VOLTAGE TRANSDUCER
Converts a single phase, 120 VAC,
60 Hz power systems to a propor-
tional 0 to 5 volt DC output.
0 to 150 V
79mm x 51mm x
104mm (
3.1” x 2.0” x
4.1”)
SRP3, SR7, SRP7,
OWL 400
VT-1P 35-0110
1
480 VAC, 60 HZ THREE PHASE VOLTAGE TRANSDUCER
Converts a three phase, 480 VAC,
60 Hz power system to three pro-
portional 0 to 5 volt DC outputs.
(Not exactly as shown).
0 to 600 V (3-phase)
112mm x 97mm x
119mm (
4.4” x 3.8” x
4.7”)
SRP3, SR7, SRP7 VT-3P 35-0120
SENSORS: Electrical – AC Current
2
250 AMP, 60 HZ AC CURRENT PROBE AND 250 AMP, 50 HZ AC CURRENT PROBE
To easily data log AC current, simply
clamp the ACR Current Probe around
the electric lead. No tools or wiring
required, permitting safe and reliable
operation. Operating amperage
ranges are switch selectable.
5, 25, 100, 250 Amps 1.5 m (5’)
Clamp inside
diameter: 2.5 cm (1”)
SR3, SRP3,
OWL 300
A60FL (60 Hz version)
OWL-A60FL*
A65FL (50 Hz version)
OWL-A65FL*
35-0004
01-0000
35-0006
01-0002
2
500 AMP, 60 HZ AC CURRENT PROBE AND 500 AMP, 50 HZ AC CURRENT PROBE
To easily data log AC current, simply
clamp the ACR Current Probe around
the electric lead. No tools or wiring
required, permitting safe and reliable
operation. Operating amperage
ranges are switch selectable.
10, 50, 250, 500 Amps 1.5 m (5’)
Clamp inside
diameter: 5cm (2”)
SR3, SRP3,
OWL 300
A70FL (60 Hz version)
OWL-A70FL*
A75FL (50 Hz version).
OWL-A75FL*
35-0005
01-0001
35-0007
01-0003
4
AMPROBE 50 TO 1 CURRENT TRANSFORMER
Extends the AC current sensing
range of an ACR Current Probe by
50 times up to 3000 Amps maxi-
mum continuous duty. Must be
clamped around an A60, A65, A70,
or A75 FL Current Probe.
Up to 3000 Amps Any ACR Current Probe CT-50-2
38-0000
3
LINE SPLITTER/MULTIPLIER - 120 VOLT 60 HZ AND EUROPEAN VERSION
To quickly monitor the AC current
in-line on any convenience outlet,
simply plug the splitter in between
the outlet and the equipment that is
being monitored. For monitoring
very small loads, there is a 10x mul-
tiplier slot for increased sensitivity.
No wiring, safe to use.
N/A N/A A60FL and A70FL
A65FL and A75FL
A-47L
A-47CL
38-0001
38-0002
*OWL current probes require an IP-67 connector. The cable length is 2 meters (6 feet). Note the different model and catalog numbers when ordering.
SENSORS: Miscellaneous
5
OCCUPANCY DETECTOR
Detect if a room is occupied and log
it with no tools or wiring. The sensor
is self-powered with a user replace-
able battery. Plugs directly into ACR
process signal data loggers. Used in
energy management studies and
security situations.
0-10 m (0-30’) 30 cm (12”) SR7, SRP7, OWL 400 OC-DET-100 01-0100
2.5 m (8’)
Clamp inside
diameter: 9.8 cm (3-7/8”)