Specifications
FEATURES/DESCRIPTION
RANGE COMPATIBILITY MODEL CAT. NO.LENGTH/SIZE
41
Accessories
1
J TYPE WELDED TIP THERMOCOUPLE WIRE
Wire is 20 gauge with duplex
insulated Teflon® jacket.
-50 to 600°C (-55 to 1100°F) 30 cm (12”) SR5, SR6, SRP5,
SRP6
TCJ-Welded 01-0102
1
K TYPE WELDED TIP THERMOCOUPLE WIRE
Ideal for high temperature applica-
tions. Wire is 20 gauge with
duplex insulated Teflon® jacket.
-100 to 1150°C
(-145 to 2100°F)
30 cm (12”) SR5, SR6, SRP5,
SRP6.
TCK-Welded 01-0103
1
T TYPE WELDED TIP THERMOCOUPLE WIRE
Ideal for low temperature applica-
tions. Wire is 20 gauge with
duplex insulated PVC jacket.
-200 to 400°C
(-325 to 750°F)
30 cm (12”) SR5, SR6, SRP5,
SRP6
TCT-Welded 01-0104
2
J TYPE BULK THERMOCOUPLE WIRE
Wire is 20 gauge with duplex insu-
lated Teflon® jacket. Customer
must either twist or weld the tip.
-50 to 600°C
(-55 to 1100°F)
Specify length in feet SR5, SR6, SRP5,
SRP6
TCJ 31-0014
2
K TYPE BULK THERMOCOUPLE WIRE
Ideal for high temperature applica-
tions. Wire is 20 gauge with duplex
insulated Teflon® jacket. Customer
must either twist or weld the tip.
-100 to 1150°C
(-145 to 2100°F)
Specify length in feet SR5, SR6, SRP5,
SRP6
TCK 31-0015
2
T TYPE BULK THERMOCOUPLE WIRE
Ideal for low temperature applica-
tions. Wire is 20 gauge with duplex
insulated PVC jacket. Customer
must either twist or weld the tip.
-200 to 400°C
(-325 to 750°F)
Specify length in feet SR5, SR6, SRP5,
SRP6
TCT
31-0016
1
THERMOCOUPLE TIP WELDING SERVICE
ACR can weld any thermocouple tip.
Provides the best contact, prevent-
ing contaminants from affecting sen-
sor reliability.
N/A Order thermocouple
wire separately
J, K, and T type
thermocouples
TC-Weld
89-0003
SENSORS: Temperature – Thermocouple Type
SENSORS: Relative Humidity
3
PLUG-IN REPLACEMENT RH SENSOR FOR POST 20,000 SERIAL # LOGGERS
Relative humidity sensing element
that simply plugs into the existing
RH sensor port on compatible ACR
RH data loggers. The sensor is
equipped with a filter to protect it
from many contaminants. For envi-
ronmental susceptibility, see any
ACR RH data logger specification.
10 to 90% RH and
-20 to 40°C (-4 to 104°F)
N/A SR2, SR4, SRP2 RH-002
35-0009
4
REMOTE RH AND TEMPERATURE SENSING PROBE FOR POST 20,000 SERIAL # LOGGERS
An external Relative Humidity and
Temperature Probe for tight or
remote locations. Every RH read-
ing is temperature compensated for
accurate readings. For environ-
mental susceptibility, see any ACR
RH data logger specification.
Maximum extension is 30m (100’).
10 to 90% RH and
-20 to 40°C (-4 to 104°F)
90 cm (3’) SR2, SR4, SRP2,
SRP4*
*(except SRP4 LPD)
EH-020A
01-0040
2
RH CALIBRATION SERVICE
Recalibration for ACR RH data
loggers and external RH Probes.
A 3-point calibration is performed
against a NIST traceable refer-
ence sensor.
N/A N/A SR2, SR4, SRP2,
SRP4, EH-020A
RH-CALIB
Call for
RMA #
1
2
3
4