User Guide

Y1-03-0165 Rev. B
10
3. Inspect O-Ring seal for proper fit. Lubricate with silicone grease.
F. Replace the battery by securing the two terminals to the battery posts. Assure tightness.
NOTE: Connect black lead to center (-) post of battery. Connect red lead to outer (+) post of battery.
G. Check for proper operation by holding the top cap assembly vertical (light lens up). The unit
should flash about once each second. If the unit does not operate, check for proper battery
connection.
3.4 ASSEMBLY
Hold the case horizontally and slide the battery in, terminal end up (towards the open end of the
case).
Lubricate the top cap O-ring with silicone grease and insert the cap and foam spacer into the case.
Place the unit upright on a firm surface, and press the top cap assembly until the cap slips into the
case. Depress the cap until the locking swivels can seat into the provided recesses. Turn the locking
swivels, seat them into the cap recesses and remove pressure from the top to allow it to move
upwards and lock. Check unit operation.
CAUTION: Assure that the locking swivels are properly seated in the cap grooves. Rotate the
cap, if necessary, to assure proper seating of the swivels.