Specifications

SAFETY & NAVIGATION
677
Detectors
Marine Technologies Fume Detector
ThisU.L.listedfumedetectorisdesignedtot
in standard 2-1/8" instrument hole. The SA-1 is a
remote sensor system that also allows the addition
of a second sensor to monitor a separate area.
You can even add another remote display for dual
station/helm. Kit includes dash mounted panel, sensor assembly,
and a 20' plug-in cable.
7 - 16V, .2 amp draw•
Detects, gasoline, hydrogen, propane, alcohol, acetone, •
methane and other explosive vapours.
MTI SA-1
Accessories:
MTI SA-1-R Second station display w/ cable
MTI SA186-SB Sensor/replacement sensor w/ cable
Fireboy/Xintex
Carbon Monoxide Detector
The CMD-1MR-9V is a 9V battery powered carbon
monoxide detector. Uses an advanced biomimetic
sensor to determine CO levels. Time Weighted
Average sensor technology is used to eliminate false alarms.
Extremely low battery consumption – only .016 mA •
9V battery is included•
Install one unit in each separate area•
Ceiling or wall mount•
85 dB alarm @ 10% CO2 saturation•
4.75” Diameter x 1.5” Depth•
FBY CMD-1MR-9V
Fireboy/Xintex
Carbon Monoxide Sentinel
The CMD-4MR carbon monoxide detector is ideal
when generator shutdown and multiple location
warning are not desired. 12 VDC operation. Features
a state-of-the-art sensor that is unaffected by
common cleaning solvents. Lowest current draw of
any Fireboy-Xintex CO Detector (16mA average). UL 2034 Listed
for Marine use. 85dB @ 10'.
3.5” L x 2.4” W x 1.3” D•
FBY CMD-4MR
Marine Technologies Carbon Monoxide Detector
Carbon monoxide gas is potentially lethal, and
produced by a number of sources on the average
boat, including cooking stoves, defective exhaust
systems, space heaters, portable grills and other
vessels moored nearby. These UL listed units
feature a low current draw of only 60 mA, with an
operational range of 8-16 volts. The alarm is an
unmistakable 85db @ 10'.
Memory scan retains CO level that activated alarm•
Operates during mute•
U.L. Listed•
Meets A.B.Y.C. Standards•
MTI 60-541 Surface mount. 5.5" x 3" x 1.3"
MTI 60-542 Flush mount. 6.5" x 3.5" x 1.25"
Marine Technologies
Propane & Natural Gas Detectors
Low power draw propane & gas detectors keep
you and your investment safe. Comes complete
with a test circuit, safe-T-lock, mute circuit and
double check circuit. Does not use a remote sensor.
U.L. listed. 85db.
Current draw: .046 amp
5.5" x 3" x 1.4"•
MTI 40-441RV Surface mount
MTI 40-442RV Flush mount
BEP Contour Matrix Gas Detector
Unitscanbettedtoasurfacewithminimum
protrusion or recessed into a panel. The BEP
Detector uses microprocessor control to ensure
correct sensor sensitivity. The Detector has
the capability to control two sensors which
detect both LPG and gasoline , with visual
and audible alarms (unit is supplied with one sensor). There is a
test switch to check operation of sensors with indicators for fault
detection. It also has provision for the connection of an external
alarm and bilge blower.
Power supply: 10V min to 35V max•
Current draw: 140mA with dual sensors •
(340mA when gas is on)
Alarm sensitivity: 20% LEL (Lower Explosive Limit)•
Current at outputs: 800mA maximum•
W: 8.8 cm x H: 6.6 cm•
BEP 600-GD
Propane Solenoid Valve
A U.L. listed, 12 volt solenoid with automatic
fail-safe feature.
Power requirements: 6 watts•
Current: .6 amps•
Maximum pressure: 312 psi.•
Mount on tank side of LPG regulator•
In-line 1/4" IPT ports. Normally closed•
PRP SV-S121
Seaward Propane Panel
LPG electric panel with 5 amp reset fuse,
on-off switch and on indicator light.
4-1/2" W x 3-1/4" H•
SWD 93156
BEP Gas Detector Sensor
For use with the 600-GL or GDL
detectors for a secondary input
BEP BL-SL-L