TABLE OF CONTENTS Message from the President 1 Product and Market Overview 2-3 Product Selection Guide 4-5 Multi-Channel Data Loggers SmartReader SmartReader SmartReader SmartReader TRH-1000 Plus Common Specs Plus 1-10 Common Specs 1-9 6 7-14 15 16-19 20 Single Channel Data Loggers JR-1000/1001 Nautilus85/135 OWL Common Specs OWL 100-500 SmartButton 21 22 23 24-26 27 Specialty Products Conservation Logger IAQ Logger PowerWatch 28 29 30 Software PowerWatch Software TrendReader® 2 TrendReader® Expr
Message from the President ACR Systems Inc. has come a long way since we started designing and building data loggers in 1986. The fundamental values we established at our beginning – customer focus and dedication to quality – made it possible for ACR Systems to become one of the world’s leading manufacturers of compact, portable and self-powered data loggers.
Proven Performers in a Wide Range of Applications Product Overview ACR Systems is the original manufacturer and pioneer of portable data loggers with an extensive product line to meet a variety of customers' needs. From low-cost, single channel data loggers to high-end multi-channel and multi-functioning data loggers, ACR has the right product for you.
Market Overview ACR data loggers are recognized globally as the premium instrument of its kind and proven performers in a wide range of applications. The following represents the core markets in which ACR serves and the typical applications requiring the use of our data loggers.
Product Selection Guide CHANNELS MEASUREMENT RANGE RESOLUTION MEMORY (MAX.) 1 -40 to 85ºC (-40 to 185ºF) 8 Bit JR-1000/1001 1 -40 to 85ºC (-40 to 185ºF) 8 Bit 32 KB OWL 100 1 -40 to 70ºC (-40 to 158ºF) 8 Bit 32 KB TEMPERATURE SmartButton 2 KB Thermistor OWL 200 1 -60 to 255ºC (-76 to 491ºF) 8 Bit 32 KB SmartReader 1 2 -60 to 255ºC (-76 to 491ºF) 8 Bit 32 KB SmartReader Plus 1 2 -60 to 255ºC (-76 to 491ºF) 12 Bit 1.
# OF READINGS (MAX.) 2,048 SAMPLING RATE SECONDARY CHANNEL(S) 1 to 255 minutes n/a 244,800 8 seconds to 34 minutes 32,767 0.2 seconds to 12 hours 32,767 BATTERY LIFE PAGE # 1 yr 28 n/a 5 yr 22 n/a 10 yr 25 0.2 seconds to 12 hours n/a 10 yr 25 32,767 8 seconds to 120 hours External temperature 10 yr 16 1,048,000 0.04 seconds to 8 hours External temperature 10 yr 7 32,767 8 seconds to 120 hours External temperature 10 yr 20 1,048,000 0.
SmartReader Plus - Common Specifications Multi-Channel, Configurable, 12-Bit Data Loggers FEATURES • Multiple channels Front Back Removable screw-type terminal block for easy connections Locking eyelet Magnetic backing • Monitor a variety of parameters: - Temperature Relative Humidity Current Voltage Pressure Process Signals Pulse • 12-bit resolution • 10-year battery life Rugged Noryl® enclosure Internal thermistor temperature sensor Unique serial number Input jack for interface cable • 3-year w
SmartReader Plus 1 Two-Channel Temperature (Thermistor) Data Logger FEATURES The SmartReader Plus 1 data logger is specifically designed for easy monitoring and recording of temperature. With one internal ambient temperature channel and one input for optional remote temperature or contact closure sensing, this data logger is ideal for quick and accurate temperature recordings in a variety of applications. • Two channels • Monitor and record temperature P R O D U C T S P E C I F I C AT I O N S No.
SmartReader Plus 3 FEATURES Eight-Channel AC Current and Voltage Data Logger • Eight channels • Monitor current and voltage (single or 3-phase) The SmartReader Plus 3 easily and accurately records AC current and voltage. Simply connect ACR’s current probes (which are clamped around the power leads) and ACR’s voltage transducer to the data logger and begin recording.
SmartReader Plus 4 Four-Channel Pressure, Temperature and Relative Humidity Data Logger FEATURES • Four channels The SmartReader Plus 4 data logger provides easy monitoring and troubleshooting of pneumatic control systems. The unit is completely self-contained with a 1/4” quick-release pressure fitting to allow a fast and trouble-free connection.
SmartReader Plus 4 LPD FEATURES Two-Channel Low Pressure Differential Data Logger • Two channels The SmartReader Plus 4 LPD data logger is designed to be used in applications where very precise, low differential pressure measurements are required. • Monitor very low pressure - several ranges to choose from • Very precise and accurate measurements • Extra fine pressure resolution • Temperature compensated P R O D U C T S P E C I F I C AT I O N S No.
SmartReader Plus 5 Three-Channel Temperature (Thermocouple) Data Logger The SmartReader Plus 5 data logger is ideal for those applications that require monitoring high temperatures or monitoring temperature over a wide range. The logger has one internal channel for measuring ambient temperature and two external channels for use with ACR thermocouple wire or any J, K, S, T or E type thermocouple wire.
SmartReader Plus 7 FEATURES Eight-Channel Process Signal Data Logger • Eight channels The SmartReader Plus 7 records a variety of different process signals including the popular 4-20mA and 0-5V. With seven input channels it is ideal for monitoring (through commercially available transducers) a wide variety of measurement parameters such as flow, level, pressure, and much more.
SmartReader Plus 8 Eight-Channel Temperature (Thermistor) Data Logger FEATURES The SmartReader Plus 8 data logger can measure temperature in eight different locations simultaneously using ACR’s ET series thermistor probes. Monitor and record high temperature, low temperature, pipe surface, skin surface, or a variety of other temperatures. • Eight channels P R O D U C T S P E C I F I C AT I O N S • Use with a variety of different temperature probes: No.
SmartReader Plus 10 FEATURES Four-Channel Temperature (RTD) Data Logger • Four channels The SmartReader Plus 10 data logger is designed to precisely measure temperature over a wider temperature range than a thermistor without sacrificing accuracy or resolution. With four channels, measurements can be made in several different locations.
SmartReader - Common Specifications Multi-Channel, Configurable, 8-Bit Data Loggers Removable screw-type terminal block for easy connections Front Back FEATURES Locking eyelet • Multiple channels Magnetic backing • Monitor a variety of parameters: - Rugged Noryl® enclosure • 8-bit resolution Internal thermistor temperature sensor Unique serial number Input jack for interface cable SmartReader data loggers share many common features.
SmartReader 1 FEATURES Two-Channel Temperature (Thermistor) Data Logger • Two channels The SmartReader 1 data logger is a simple and easy-to-use data logger for monitoring and recording temperature. Quick and easy to set up, it works right out of the box, logging temperature readings from its internal, precision-calibrated temperature sensor. For added versatility, use the extra channel to record temperature (with an ACR thermistor probe), resistance or switch status.
SmartReader 3 Four-Channel AC Current Data Logger FEATURES The SmartReader 3 data logger easily and conveniently records AC current. Simply connect the data logger to three ACR current probes (which are clamped around power leads) and begin recording three-phase systems or related equipment simultaneously. The probes allow accurate readings to be taken without interrupting any circuits. The logger also records ambient temperature.
SmartReader 5 Three-Channel Temperature (Thermocouple) Data Logger FEATURES • Three channels • Monitor extremely high temperatures • Monitor temperature over a wide range • Use with a variety of different thermocouple probes The SmartReader 5 data logger is ideal for those applications that require monitoring extremely high temperatures or monitoring temperatures over a wide range.
SmartReader 8 Eight-Channel Temperature (Thermistor) Data Logger FEATURES The SmartReader 8 data logger can measure temperature in eight different locations simultaneously using ACR’s ET series thermistor probes. Monitor and record high temperature, low temperature, pipe surface, skin surface, or a variety of other temperatures. • Eight channels • Monitor temperature in eight different locations P R O D U C T S P E C I F I C AT I O N S No.
THR-1000 Two-Channel Temperature and Relative Humidity Data Logger F E AT U R E S • Low-cost temperature and RH logger Built-in temperature and relative humidity sensors • Easy to use • No accessories required • 5-year battery life • User selectable sample method and rate • NIST certificates available on special request Serial port plug The TRH-1000 is a low-cost, easy-to-use temperature and relative humidity data logger.
JR-1000 / JR-1001(Intrinsically Safe) Single Channel Temperature Data Logger F E AT U R E S • Low-cost logger Serial port plug • Intrinsically Safe version available (JR-1001) Rigid polyurethane encapsulation • 5-year battery life • User configurable Built-in temperature sensor General Purpose Intrinsically Safe The JR-1000 series is the easiest to use temperature data logger available.
Nautilus85 / Nautilus135 Single Channel, Waterproof, Temperature Data Loggers FEATURES Outside • Monitor temperature in water, food or other liquids Inside Temperature sensor location Input jack for interface cable • Available in stainless steel or aluminum • Extremely durable and robust • 10 year battery life • Data compression capability Anodized aluminum or stainless steel enclosure Mounting hole for hook or string • Holds over 500 days of data • User selectable sample methods and rates The Nauti
OWL - Common Specifications Single Channel, Configurable, 8-Bit Data Loggers FEATURES • Single channel Front • Monitor temperature, current, voltage or process signals Back • 10-year battery life Optical port/alarm Visual serial number identification Magnetic backing • Flashing visual alarm • Memory capacity of 32,767 readings • Optical data transfer • Fast sample capability Sensor/Connector Convenient security lock P R O D U C T S P E C I F I C AT I O N S OWL data loggers share many common featur
OWL 100 Single Channel Ambient Temperature Data Logger FEATURES • Compact and small, monitor temperature virtually anywhere • Water-resistant version available The OWL 100 data logger records temperature in environments that typical data loggers cannot withstand. This model is also available in a water-resistant polyurethane enclosure (OWL 100-Poly) so it can be used in hostile environments where vibration or excess moisture is present.
OWL 300 Single Channel AC Current Data Logger FEATURES The OWL 300 data logger records electric current in applications where typical data loggers cannot fit. Due to its small size, the OWL 300 can go directly into an electrical panel or even inside small electrical equipment allowing the user to record electric current in a safe, discreet, and convenient manner. • Monitor a wide range of AC current • Sense AC current from inside equipment P R O D U C T S P E C I F I C AT I O N S Accuracy: +/- 4% F.S.
OWL 500 FEATURES • Connect virtually any device that has a 4-20mA output • Record a variety of parameters (i.e. flow, level, pressure, etc.) Single Channel Process Signal (4-20mA) Data Logger The OWL 500 is a rugged and versatile data logger that records the popular 420mA process signal with ease and convenience. It is ideal for monitoring (through commercially available transducers) a wide variety of measurement parameters.
SmartButton Single Channel Temperature Data Logger FEATURES • Extremely small and low cost The ACR SmartButton is a miniature-sized temperature logger that is extremely low-cost and easy to use. Because of their small size and low-cost, you can purchase tens or hundreds of them for multiple-site temperature monitoring. To get you started, purchase the SmartButton Starter Pack. It includes one SmartButton, an interface cable, the SmartButton Reader software, and a mini manual.
Conservation Logger Five-Channel Temperature, RH and 5V Input Data Logger FEATURES • Monitor and record temperature, RH and any parameter with a 0-5VDC output • Visual alarm • 12-bit resolution • 5-year battery life • 128 KB memory (87,000 readings) • Fast sample rates (up to 25 samples per second) • Network capable • Remote access via modem or Ethernet • User configurable The Conservation Logger is a self-contained temperature and relative humidity logger with two external channels for use with a variety
IAQ Logger Temperature, Humidity and CO2 Data Logging Solution • Monitor and record indoor air quality: The IAQ Logger, when combined with the Telaire 7001 Handheld CO2 Monitor, records the three leading indicators of indoor air quality: (1) temperature, (2) relative humidity, and (3) carbon dioxide. This IAQ solution is ideal for those applications requiring long-term, close monitoring and recording. Quickly and easily verify the temperature and CO2 on the Telaire’s large, easy-to-read display.
PowerWatch Voltage Disturbance Recorder Front Back FEATURES • Records essential voltage disturbance events: - Surges Sags Outages Dropouts Impulses Frequency variations • Records up to 4000 events • 10-year battery life • Safe, stand-alone operation • No wires, alligator clips or other exposed wiring • Hot-Neutral and Neutral-Ground monitoring North America 120 Volt Australia 240 Volt United Kingdom 240 Volt Continental Europe 240 Volt Use the PowerWatch as your first line of defence against power
PowerWatch Software For PowerWatch Voltage Disturbance Recorder Compatible with Windows® 2000 SP4, XP SP3 and Vista 32 bit • Simple and easy to use This powerful and easy-to-use power quality analysis software program is developed exclusively for ACR’s voltage disturbance recorder, the PowerWatch. With no programming hassles or complex menus, setup and downloading occurs in seconds.
TrendReader® 2 Software For SmartReader Plus, SmartReader, IAQ, OWL, TRH, JR and Nautilus Data Loggers - Compatible with Windows® XP SP3, Windows FEATURES • Serial & USB port interface • Fast and easy logger setup • One-touch table views • Presentation-quality graphs • Multi-graph display • Zooming capabilities • Export capabilities (TXT, BMP, PDF, JPG or CSV formats) • Real-time readings Vista SP2, Windows 7 (32 and 64 bit versions) TrendReader® 2 is a powerful, versatile, and easy-to-use software packag
TrendReader® Express Software –For JR-1000/1001, Nautilus85/135 and TRH-1000 Data Loggers - Compatible with Windows® 2000 SP4, XP SP1 and Vista 32 bit TrendReader® Express is an enhanced software package designed exclusively for the JR-1000/1001, Nautilus85/135 and TRH-1000 data loggers. This easy-touse software incorporates the advantages of simple functionality with advanced features that are normally associated with more expensive data acquisition software.
TalkBack Software For SmartReader Plus Data Loggers FEATURES TalkBack software has two main features: (1) it automatically downloads logged information from any SmartReader Plus data logger and (2) it responds to SmartReader Plus alarms. TalkBack also works with SRP data loggers that are on a local or remote network.
Networking and Remote Communications For SmartReader Plus Data Loggers Convenient method of connecting up to 10 Networkable Data Loggers up to 200ft (60m) hooked to a remote modem. FEATURES • Up to 10 loggers (80 channels) on one network • Compatible with any modem • Automatic data download • Simple wiring; no hub required Notes: 1. 2. 3. 4.
SRP Display Module For SmartReader Plus Data Loggers FEATURES • View real-time readings • For use with SmartReader Plus data loggers • Portable, battery powered and easy to use • For verification and spot-checking purposes • Optional power supply for continuous visual display The SRP Display Module is an external display option for the SmartReader Plus line of data loggers. It is designed to let you view real-time readings of an SRP data logger.
Alarm Module 100 For SmartReader Plus Data Loggers FEATURES The Alarm Module is intended for use with the SmartReader Plus line of data loggers. It utilizes the alarm dial-out capability of the SRP data loggers, providing a blinking LED light and audio beeper to indicate that an alarm threshold has been tripped. The Alarm Module stays in alarm state until the reset button has been pressed. Additionally, two sets of relay contacts are provided for general purpose use.
Accessories FEATURES/DESCRIPTION RANGE/ACCURACY LENGTH/SIZE COMPATIBILITY MODEL CAT. NO.
Accessories FEATURES/DESCRIPTION RANGE LENGTH/SIZE COMPATIBILITY MODEL CAT. NO. SENSORS: Temperature – Thermocouple Type 1 * NOTE: The maximum temperature tolerance for the thermocouple wire jacket is 200°C (392°F) 1 J TYPE WELDED TIP THERMOCOUPLE WIRE Wire is 20 gauge with duplex insulated Teflon® jacket*.
Accessories FEATURES/DESCRIPTION RANGE LENGTH/SIZE COMPATIBILITY MODEL CAT. NO. SRP3, SR7, SRP7, OWL 400 VT-1P 35-0110 SRP3, SR7, SRP7 VT-3P 35-0120 SENSORS: Electrical – AC Voltage 1 1 1 2 0 VA C , 6 0 H Z S I N G L E P H A S E V O LTA G E T R A N S D U C E R Converts a single phase, 120 VAC, 60 Hz power systems to a proportional 0 to 5 volt DC output. 2 0 to 150 V 79mm x 51mm x 104mm (3.1” x 2.0” x 4.
Accessories FEATURES/DESCRIPTION RANGE LENGTH/SIZE COMPATIBILITY MODEL CAT. NO. SENSORS: SmartReader – Pressure 1 SMARTREADER 4 PRESSURE MODULES Plug-in pressure modules for any SmartReader 4 data logger (not compatible with SmartReader Plus 4). Available in Absolute and Gauge. Comes with a quick release pressure hose connector (not shown).
Accessories FEATURES/DESCRIPTION RANGE LENGTH/SIZE COMPATIBILITY MODEL CAT. NO. N/A SR, SRP TB-11 29-0004 SR, SRP STR-11 29-0013 N/A Any temperature or RH probe. Other products may be extended. Call for compatibility. DS-1822 18-0019 N/A Any ACR data logger with a terminal block. SD-100 21-0059 SR, SRP, Nautilus IC-101 01-0068 SR, SRP, Nautilus IC 102 01-0088 OWL and PowerWatch LIC-101 01-0023 1.8 meters (6 feet) OWL and PowerWatch LIC-102 01-0232 1.
Accessories FEATURES/DESCRIPTION RANGE LENGTH/SIZE COMPATIBILITY MODEL CAT. NO. COMMUNICATIONS: All Loggers - Logger to PC 13 13 U S B S E R I A L A D A P T E R Allows communication with an ACR data logger through USB for computers that do not have a serial port.
Accessories FEATURES/DESCRIPTION RANGE LENGTH/SIZE COMPATIBILITY MODEL CAT. NO. N/A SR, SRP USM-C 01-0300 N/A N/A SR, SRP USM-R 01-0301 N/A N/A SR, SRP MA-100 18-0023 SR, SRP, JR1000/1001, and OWL WB-100 01-0057 COMMUNICATIONS: Remote Communications 1 1 C O M P U T E R S TAT I O N M O D E M External modem for use with a PC factory programmed for communication with ACR data logger networks.
Accessories FEATURES/DESCRIPTION RANGE LENGTH/SIZE COMPATIBILITY MODEL CAT. NO. MISCELLANEOUS: PowerWatch – Adapters cont. 1 1 SOCKET ADAPTER STYLE #3 Plugs into the Schuko (Europe) version of PowerWatch to convert the plug-in connection. 240 Volt Swiss N/A PowerWatch (Europe version) PWA-003 21-0040 2 MISCELLANEOUS: Other 2 FA S T S A M P L I N G B AT T E RY PA C K SmartReader Plus data loggers require the BP-101 Battery Pack to log at rates faster than once every 8 seconds.
Reference Temperature Accuracy Curves The internal temperature sensor located in almost all ACR data loggers is the ET-016 thermistor. Thermistors are non-linear which means the accuracy of the sensor varies over the entire temperature range of the logger. The graph below outlines the accuracy curves for the ET-016 thermistor. ACR data loggers with this thermistor onboard include: SmartReader, SmartReader Plus, OWL (if using standard range), JR, and Nautilus.
ACR Systems Inc. Our Quality and Customer Service Commitment ACR Systems' products are extremely accurate measurement tools for engineers, technicians, scientists, managers, and just about anyone who needs to log data that is crucial to solving problems and improving performance in their company and/or application. As an ISO 9001 company, ACR Systems is committed to quality: quality products, quality service, and quality management and operations.