User Guide

Installation Manual 39 Y1-03-0212 Rev.B
Select Submenu 1 “General Settings” with cursor button [Up] & [Down] by pressing Nr. 1 on
the keyboard.
Scroll the Data Fields with [Enter] and input own vessel data. Enter a SOLAS draught in
meter (max. = 25.5m), a Inland draught in centimetre (max. = 2000cm) and air-draught value
in centimetre (max. = 4000cm) as well as the correct navigational status setting.
Save the new settings by pressing [Save], and return to the Main Menu Screen by pressing
[Exit]. Press [Back] to return to the Main Menu without saving any changes.
Select Submenu 2 “Cargo/Voyage Settings” with cursor button [Up] & [Down] or by pressing
Nr. 2 on the keyboard.
Toggle the values for the ERI ship type, the hazardous cargo (number of blue cones) and the
loaded / unloaded status.
Save the new settings by pressing [Save], and return to the Main Menu Screen by pressing
[Exit]. Press [Back] to return to the Main Menu without saving any changes.
Select Submenu 3 “Persons on Board” with cursor button [Up] & [Down] or by pressing Nr. 2
on the keyboard.
N 1^18' E 0^12' |1>0.01|2>1.30|3>1.80nm
***********General Settings*************
SOLAS Draught:>=25.5m
INLAND Draught:=>2000cm
Airdrauht :=>4000cm
NavStat. :<under way using engine>
BlueSign : used
----------------------------------------
| Save | | | Back
N 1^18' E 0^12' |1>0.01|2>1.30|3>1.80nm
********* Cargo/Voyage Settings ********
ERI ship type :<Vessel type unknown>
Hazardous cargo:<default unknown>
Un/ Loaded :<loaded> / <unloaded>
----------------------------------------