Service manual

LUMISCAN ACR-2000 SERVICE MANUAL - SECTION 2.0 INSTALLATION
2-7
Copy the CLUT file (CLTXXXXX.DAT) from the floppy distribution disk into the directory,
\SystemRoot\system32\drivers. Use the LSDT for Windows NT Control Panel(see below) to
enter this filename into the LSDT section of the Registry.
Copy the CAL LUT (CALXXXXX.DAT) from the floppy distribution disk into the directory,
\SystemRoot\system32\drivers. Use the LSDT for Windows NT Control Panel(see below) to
enter this table into the LSDT section of the Registry.
NOTE
If the specified CLUT file is not found when the driver loads, the driver will default to
a 1:1 Correction LUT and a warning message will be logged to the Event Logger.
2.3.4 Data Control Board Resources
The Data Control Board is factory configured to use IRQ 5 , I/O Addresses 100-11F and has a 32
KByte window segment at hex address D000-D7FF. If these addresses conflict with your system
configuration they may be changed. The hardware configuration is determined by a DIP switch and an IRQ
jumper on the Data Control Board. Please see APPENDIX A for instructions on how to change the IRQ
level, the I/O address, or the 32 Kbyte window address.
The most common alternates to the default resources are IRQ 7, I/O Address 120, and Segment
Address D800.
If the Data Control Board is reconfigured to use different resources, LSDT Control Panel must reflect
the change also.