Instruction manual
8
* Motor current only at high speed
**Suffix with –SM for SmartElec2 Energy Saving Control.
3.2
ACR100SE9 ACR150SE12 ACR200SE18
General Data
Maximum height M 3.0
Door width M 1.2 1.5 2.0
Heat medium Electric heated
Heat setting kW 4.5 / 9 6 / 12 9 / 18
Fan type / dia Crossflow / 100mm
Fan settings 3
Switching type AC-ACR-PANEL / SmartElec2
Weight kg 28.0 34.0 49.0
Electrical Data
Supply voltage 415V 3ph 50Hz
Total load
kW 9.1 12.1 18.1
A/pha 12.6 16.8 25.2
Motor power W 60 90
Max Starting current* amps 0.96 1.5
Max Running current* amps 0.65 0.75
External fuse size amps A/pha 16 20 32
Programmer keypad pt. no. AC-ACR-PANEL
Program keypad control wiring Screened twisted pair 28AWG
Cable terminal size 6.0mm² Max
Mains terminal block position
Bottom of base unit.
Terminals N; L1; L2 & L3
Separate din rail
E: N; L1; L2 & L3
Control terminal block position Right side of base unit terminals +12V, DATA & GND
*** SmartElec Energy Saving Control pt. no. SELEC2BU
SmartElec Energy Saving Control wiring 4 core pre-wired
Cable terminal size 10.0mm² Max
Mains terminal block position SmartElec2 Base Unit - terminals N; L1; L2 & L3
Control terminal block position SmartElec2 Base Unit
Air Data
Air volume
Low speed
m³/h 1164 1475 2013
Medium speed
m³/h 1405 1780 2432
High speed
m³/h 1646 2085 2851
Air velocity
Low @ 0M
m/s 4.3 5.4
Medium @ 0M
m/s 5.6 6.9
High @ 0M
m/s 7.0 8.4
High @ 1M
m/s 3.5 4.2
High @ 2M
m/s 1.6 2.1
High @ 3M
m/s 0.8 1.0
Delta T
Low speed
°C 26 25 21
Medium speed
°C 23 22 20
High speed
°C 20 19 19
Noise level @ 1M
in free field
Low speed
dBA 59
Medium speed
dBA 62
High speed
dBA 64
Dims Data
Length mm 1182 1482 1982
Depth (width) mm 395
Total height* mm 200
Outlet length mm 1125 1425 1945
Outlet depth (width) mm 85
Grille height mm 40
Mounting bracket centres length mm 1220 1520 2020
Side to 1
st
bracket centre mm 18
Mounting bracket centres height mm Flush with top of unit
Top to 1
st
bracket centre mm Flush with top of unit
4.0mm² Max