Instruction manual
48
10.1.1 Keypad Buttons
The button will allow you to navigate.
The button will allow you to increase the setting.
The button will allow you to decrease the setting.
10.1.2 Operation
On first power up, the display panel will have the
following default settings:
F. 0 (no fan)
H. 0 (no heat)
1. 16 (°C. Heat set point - Auto mode only)
2. 7 (°C. half heat set point - Auto mode only)
D. 2 (fan speed in door switch mode)
Note: Subsequent power ups will retain any entered
settings in the display panel internal memory.
Press the or
buttons to toggle between the
‘F’ (Fan), ‘H’ (Heat) and On/Off Parameters.
Prefix ‘F’ denotes the FAN SPEED. This can be either
1: slow ; 2: medium or 3: fast speed. 0 setting denotes
the unit is
OFF.
To alter the current speed, press the button. The
value will start flashing.
Press the or
buttons to increase/decrease the
desired setting.
Press the button to confirm new setting. A delay of
7 seconds will return to the original display.
Prefix ‘H’ denotes the HEAT setting. This can be either
1: low heat; or 2: high heat. 0 setting denotes the unit is
set at fan only.
To alter the current setting, press the button. The
value will start flashing.
Press the or
buttons to increase/decrease the
desired setting.
Press the button to confirm new setting. A delay of
7 seconds will return to the original display.
10. User Instructions.
fig.12. AC-ACR-PANEL Programmer