Product Manual
9 Y1-03-0171 Rev. A
Activation of the SART is completed by using the three-position switch ring (TEST-OFF-ON), as
shown in figure 4.
1. Turn the Blue activation switch ring to the left, placing the SART in test mode
2. Remove the red Pull Tab by pulling it down and completely out of the SART
3. Release the activation switch and guide it to the right until it is in the ON position
a. The SART will beep once and Flash every four seconds
b. The flashing red light indicates the SART is on
Turn the bottom cap of the SART and deploy the telescopic Pole to its maximum length
( 1 meter)
Remove lanyard and secure it to the life raft
When activated the SART has three Modes of operation.
These are:
· Receive – waiting for a valid interrogation by a radar signal.
· Reply – replying to a valid interrogation by a valid radar
signal.
· Test – self-test sequence that checks both indicator lights
and the buzzer.
Sequence of Operations
The SART has a primary indicating system and secondary indicating system.
WARNING
The SART must only be used in situations of Grave and
Imminent Danger.
Figure 4