Table 5-3 Ops Panel Configuration Switch Settings for RAID
Switch
Number Function Function when Off Function when On
1 (On
a
) Loop select single
(1x16) or dual (2x8)
LRC operates as two
loops of 8 drives
LRC operates as 1 loop of 16 drives
(1x16 loop mode)
2 (On) Loop terminate mode If no signal is present on
the external FC port,
then the loop is left open
If no signal is present on the external FC port then the loop
is closed internally
3 (Off) Hub mode select
(RAID only)
Hub ports connect
independently
RAID host FC ports are linked together internally
4 (Off)Not used.
5 and 6 RAID host hub speed
select
Note: Set switches 5
and 6 to Off to force
1 Gb/s if connecting
RAID controllers to
1-Gb/s HBAs or
switches
Sw 5 Sw 6 Function
Off Off Force 1 Gb/s
On Off Force 2 Gb/s
Off On Reserved
On On Auto loop speed detect based on LRC port signals
Note: This feature is not supported
7 and 8 Drive loop speed select Sw 7 Sw 8 Function
Off Off Force 1 Gb/s
On Off Force 2 Gb/s
Off On Speed selected by EEPROM bit
On On Auto loop speed detect based on LRC port signals
Note: This feature is not supported