User`s guide

Solving Initial Startup Problems
007-4522-003 77
There is a storage system fault. See “ESI/Ops Panel LEDs and Switches” on
page 79.
There are mixed single-port and dual-ports modules within an enclosure. Only one
type of module may be installed in an enclosure.
If the SGI server does not recognize the storage system, check the following:
Ensure that the device driver for the host bus adapter board has been installed. If
the HBA was installed at the factory, this software is in place; if not, check the HBA
and the server documentation for information on the device driver.
Ensure the FC-AL interface cables from the LRC I/O module to the Fibre Channel
board in the host computer are installed correctly.
Check the selector switches on the ops panels of the storage system as follows:
On a tower or a RAID enclosure the ops panel should be set to address 1.
On the first expansion enclosure attached to a RAID system, the ops panel
should be set to address 2.
On the first enclosure in a JBOD system, the ops panel should be set to address
1. Other enclosures that are daisy chained to the first enclosure should be
addressed sequentially (2-7).
Ensure that the LEDs on all installed drive carrier modules are green. Note that the
drive LEDs flash during drive spinup.
Check that all drive carrier modules are correctly installed.
If an amber disk drive module LED drive fault is on, there is a drive fault. See
Table 5-7 on page 90.
If the SGI server connected to the storage system is reporting multiple Hard Error
(SCS_DATA_UNDERRUN) errors in the /var/adm/SYSLOG, the cabling connected to
the controller reporting the errors requires cleaning or replacement. For more
information on cleaning cables, refer to “Care and Cleaning of Optical Cables” on
page 94.