Service manual
24
Convection Fan – High Speed 
Screen This screen will allow operation of the 
convection fan at a high speed and show the 
number of amps being drawn. 
NEXT TEST:  Press this pad to go to the 
next Service Mode Test 
PREV TEST: Press this pad to go to the 
previous Service Mode Test 
TURN ON:  This pad will toggle between 
turning the convection fan on and off at a 
high speed. 
CANCEL:  Press this pad to return to the 
Main Menu 
RANGE:  Under normal operation, the amp 
draw should be 0.6 – 2.6 amps.
Cooling Fan 
Screen This screen will allow operation of the 
cooling fan show the number of amps being 
drawn.
NEXT TEST:  Press this pad to go to the 
next Service Mode Test 
PREV TEST: Press this pad to go to the 
previous Service Mode Test 
TURN ON:  This pad will toggle between 
turning the cooling fan on and off. 
CANCEL:  Press this pad to return to the 
Main Menu 
RANGE:  Under normal operation, the amp 
draw should be 0.9 – 2.5 amps.
8
9
(It may not read amps) 
(It may not read amps) 
Service Test