Service manual
23
Service Test
Radiant Heater 
Screen This screen will allow operation of the 
radiant heater and show the number of 
amps being drawn. 
NEXT TEST:  Press this pad to go to the 
next Service Mode Test 
PREV TEST: Press this pad to go to the 
previous Service Mode Test 
TURN ON:  This pad will toggle between 
turning the heater on and off. 
CANCEL:  Press this pad to return to the 
Main Menu 
RANGE:  Under normal operation, the amp 
draw should be 10 – 16 amps.
Convection Fan – Low Speed 
Screen This screen will allow operation of the 
convection fan at a low speed and show the 
number of amps being drawn. 
NEXT TEST:  Press this pad to go to the 
next Service Mode Test 
PREV TEST: Press this pad to go to the 
previous Service Mode Test 
TURN ON:  This pad will toggle between 
turning the convection fan on and off at a 
low speed. 
CANCEL:  Press this pad to return to the 
Main Menu 
RANGE:  Under normal operation, the amp 
draw is too low to read. 
6
7