Service manual
13
All Amana and Menumaster microwave oven power outputs are rated using the IEC705 
standards. Using the IEC705 test method requires precision measurements and equipment that 
is not practical to be performed in the field. Using the test shown below will indicate if the oven 
performance is satisfactory. 
Test equipment required: 
•  1000 ml test container and thermometer. 
•  Digital watch / watch with a second hand for use on ovens with electromechanical timers. 
Important Notes: 
•  Low line voltage will cause low temperature rise / power output. 
•  Ovens must be on a dedicated circuit, properly grounded, and polarized. Other equipment on the same 
circuit may cause a low temperature rise / power output. 
•  This test and results are not a true IEC705 test procedures and are only intended to provide servicers with 
an easy means of determining if the microwave oven cooking output is co
rrect. 
Procedure 
1.  Fill the test container to the 1000 ml line with cool tap water. 
NOTE:  Water temperature should be approximately 60°F / 16°C 
2. Using the thermometer, stir water for five to ten seconds; measure, and record the temperature (T1).
3.  Place test container of water in the center of oven cavity and close door. 
4.  Heat the water for a 33-second full power cycle. 
NOTE:  Use a digital watch or a watch with a second hand for ovens with electromechanical timers. 
5.  At end of the cycle, remove test container. Using the thermometer, stir water for five to ten seconds and record 
temperature (T2). 
6.  Subtract the starting water temperature (T1), from the ending water temperature (T2) to obtain the temperature 
rise (∆T). 
7.  If the temperature rise (∆T) meets or exceeds the minimum, the 
test is complete. If the temperature rise (∆T) 
fails to meet the minimum temperature rise, test the line voltage to verify it is correct. Then repeat steps 1-6 
making sure to change the water. If the temperature rise (∆T) fails to meet the minimum temperature rise again 
the oven will require service. 
Minimum Temperature Rise at Thirty -Three (33) Seconds Run Time 
∆T  Cooking  ∆T  Cooking  ∆T  Cooking  ∆T  Cooking 
(°F)  Power Output  (°F)  Power Output  (°C)  Power Output  (°C)  Power Output 
10..................1000  20 .................2000  5  ...............1000  11 ............2000 
11..................1100  21 .................2100  5.5 .............1100  11.5 .........2100 
12..................1200  22 .................2200  6.5 .............1200  12 ............2200 
14..................1400  24 .................2400  7.5 .............1400  13 ............2400 
17..................1700  25 .................2500  9.5 .............1700  13.5 .........2500 
18..................1800  27 .................2700  10
..............1800  15 ............2700 
19..................1900  30 .................3000  10.5 ...........1900  16.5 .........3000 
OVEN PERFORMANCE TEST