Specifications
FCO 2006 - AEH35 FileStore EMS
Upgrade Instructions
Ensure that the FileStore E01S unit is switched off, and disconnected from the mains, the
printer and any other FileStore units.
Prise off the back cover of the E01S unit. It is easiest to pull this backwards and downwards.
You will need to pull it quite hard to move it.
Similarly, remove the front panel, complete with the front flap. You will not be able to remove
this comp|ete|y without removing the LEDs but it is not necessary to remove the front panel
completely in any case.
Remove the two side panels.
Undo the six screws on the underside of the unit which hold the cream coloured top metal unit
to the bottom metal unit.
Slide the metal top backwards and off the main unit.
Remove the Eprom in socket 107 carefu||y, and retain it. Insert the new Eprom marked 0282,
008-01 in the socket, with pin one at the rear.
Re-assemble the unit, following the disassembly instructions in reverse. Ensure that the
connections are made from the front panel to the circuit board connectors, as these may have
been removed when removing the front panel. Ensure that the grating on the top unit is situated
at the front of the machine when assembled to keep adequate air flow.
Test the assembled unit by switching on with the front flap down, ensuring that the Mode light
remains on, then closing the flap, and checking that the unit enters user mode. If possib|e,
check using a computer that communication is possible with the computer. Remember that you
can just connect a computer fitted with an Econet interface to the FileStore - the FileStore will
provide the necessary clock signa|.
Return the removed Eprom to Acorn (Spares department). Please return in anti-static foam with
pins intact, so we can reblow the Eproms.