Service manual

Chapter 2
FileStore Service Manual 12
Half-Pulse width duration: 5Ons
Polarity: +ve or -ve
Phase Angle: Free non-synchronous
Peak Voltage: 1000V shall not cause malfunction (soft errors)
1500V shall not cause physical damage, but
visible malfunction is permitted
2.8.3 Electrostatic discharge
The equipment function is undamaged when subjected to a discharge (at both +ve and -ve
polarity) from a 5pF capacitor charged to a voltage specified below, limited by a 150
resistor. The discharge is applied to any user accessible points, interconnecting cables and
also the ground reference plane adjacent to the equipment.
Discharge Voltage: 6kV shall not cause malfunction (soft errors)
12kV shall not cause physical damage, but
visible malfunction is permitted
2.9 Environment
2.9.1 Operating
The equipment operates and functions to specification while under the following
environmental conditions:
Temperature 10 to +35C
Relative Humidity 10 to 80% non-condensing
Mechanical Shock Not operating: 40g ½ sinusoid l0ms maximum
repetition rate 1 every 10 seconds. 10 shocks on all six
faces.
Operating: 5g ½ sinusoid l0ms, maximum repetition rate
1 every 10 seconds. 10 shocks on all six faces
Vibration To BS2011 Part 2Fd, vibration in each plane (X,Y and Z).
(Time limit for each test 90 minutes)
Operating: 20 to 500Ff, O.5G max
(20 to 500Hz at 0.0005 G sq/Hz)
Not operating: 10Hz to 200 Hz at 20G max
(10Hz to 200 Hz at 0.02G sq/Hz)
2.9.2 Storage and shipping
The packaged equipment is designed and manufactured to withstand the following
conditions:
Temperature -40C to +60C
Relative Humidity 5 to 90% non-condensing
Thermal Shock 20C per hour within the range 20 +60C
Mechanical Shock Will withstand a drop of 1 metre on each face
and on the most susceptible corner