Service manual
Chapter 3 E40S/E60S Disassembly and assembly
FileStore Service Manual 93
The psu should now be free of the FileStore unit.
(9) Remove Fan (Item 34). Note that the psu needs to be removed to allow access to the fan.
Remove the four fixing (Item 63) to free the fan guard (Item 74) and fan. The fan is part
of the psu Output cable assembly and should be replaced as a complete assembly, if it is
found to be faulty.
3.2 Parts not serviceable
Faults detected in the disc drive, disc controller board or power supply, mean that the faulty
part must either be returned for repair or replaced. Dealers may hold stock of these items and
should refer to information provided by their supplier for service procedures for these units.
3.3 Assembly procedure
To reassemble the unit, simply reverse the above procedure.
When reassembling the unit, ensure that full earth testing has been satisfactorily completed.