User guide
2.
Unplug each Communicator from Econet in turn, attempting a
command such as *CAT after unplugging each one. You should get
the
Line jammed
message each time until you unplug the
Communicator that has the fault ie when the *CAT command works
without the
Line jammed
message, the last Communicator you
unplugged was the faulty one. Return the faulty Communicator to your
supplier for repair.
3.
If this does not isolate the fault, it is in the Econet cabling or FileStore
itself. Shut FileStore down and try plugging a Communicator into it
directly. If this works, there is a fault in your Econet cabling. Contact
your supplier for help.
4.
If this fails, contact your supplier to arrange further investigation and
repair.
Memory fault found
The memory components in FileStore have a fault. Contact your supplier to
arrange a repair.
Net error
There is a fault in the Econet cabling. Contact your supplier to arrange a
repair.
No clock
The 'clock' signal which Econet uses to synchronise communications (rather
like a metronome dictating the beat of a musical performance) is hot
reaching the station.
1.
Check that the station is plugged into Econet.
2.
Check that FileStore is on and plugged into Econet.
If these are not the problem, there is a fault in FileStore's clock unit. Contact
your supplier to arrange a repair.
No reply
FileStore has stopped working part way through obeying a command. Check
that FileStore is still turned on, plugged into Econet and in user mode.
Not found
A user has specified a file or directory that does not exist, usually. because
they have mistyped the name, or do not know where it is. Use
Appendix 2: DEALING WITH PROBELMS
67