User guide
10.
The prompt
should change to:
Pathname, destination file/directory
Type:
:Library
-
disc.$
11.
The prompt should now change to:
Press F6 to adjust the DATE range
Press Fl again to proceed with the COPY
Press ESCAPE to abort action
12.
Press COPY. Both disc drives should start working, as shown by their
drive activity lights and the screen should show the name of each
file/directory as it is copied.
13.
After a few minutes, the disc drives should stop and the initial
NETMGR screen should be displayed, indicating that copying is
complete.
14.
Open the access flap and remove both discs from the drives by pressing
their eject buttons. Put the Master library disc away in a safe place.
Write today's date on the Library disc you've just created. You will use
this to run FileStore.
If
your Econet
If there is already a FileStore unit on the Econet, you must make sure that the
already has a
FileStore you are adding do not interfere with each other, as follows.
FileStore
Each unit (Communicator or FileStore) connected to Econet is identified by
a unique number, in the range 1 to 254 which is called its 'station number'.
Whenever you add a unit to Econet, you must make sure that its station
number is different to all the other units' station numbers.
Check the station number(s) of the other FileStore unit(s). These should
have been written down by whoever installed them.
FileStore is delivered to you with a station number of 254. If this is already
used, you should change it to the next smallest number which is not being
used, as follows:
1. Check that FileStore is turned off. Check that any other FileStores
connected to Econet are turned off, too, or (if this is not convenient),
connect FileStore directly to a Communicator using the Econet lead.
48