Specifications

INSTALLATION:
Choose configuration; Remove and reinstall filler plate, item 23 and reverse drain assembly if
required for alternate mounting configuration.
1. Mount hanger bracket to wall horizontally level as shown in Roughing-In and Dimensional Drawing. Note:
Adjust height of bracket if bubbler outlet height is required to vary from that shown.
WARNING: Hanger Bracket MUST be securely anchored to wall with fasteners sufficient to support 3 times
the weight of cooler. If wall can not provide adequate support, order and install optional fixture support carrier.
2. Remove the bottom cover from the water cooler and set aside in a safe place. Save the screws in a secure
location for re-use in later stages of installation.
3. Hang the water coolers on the hanger brackets ensuring the bracket tabs engage AND seat in the slots in the
back of the water coolers. NOTE: Hanging of refrigerated unit first is recommended since it is the heavier of
the two. Verify water coolers are level, left to right AND front to back from bottom of unit. CAUTION: The
bubbler stream may be adversely affected if units are not square and level. Bottom of units and louvers
should be used as reference to verify unit is square and plumb.
4. Anchor the water coolers to the wall at the lower mounting points in each back panel. Shim lower mounting
points to level unit if necessary.
5. Outlet tube from evaporator has an in-line tee with a tube going to the refrigerated unit's valve and the "TEE"
not connected. Connect the loose supply tube from refrigerated unit to the "TEE".
6. Thoroughly flush the 3/8” O.D. supply line and then connect water cooler to water supply angle stop valve (by
others) with supplied 3/8” O.D. copper tube.
7. Use supplied flexible hose and clamps to connect waste tailpiece from the upper unit to the waste tailpiece of
lower unit and then make up 1-1/4” O.D. p-trap waste connection. Waste p-trap by others.
STANDARD WASTE CONFIGURATION ALTERNATE WASTE CONFIGURATION
ITEM 23
FILLER PLATE
ITEM 23
FILLER PLATE
ACORN ENGINEERING FIELD SERVICE
TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863
7020-905-001
Page 4 of 11
Date: 04/29/15
Please visit for most current specifications.www.acorndrinkingfountains.com