Installation Guide

P.
8
/
8
-
-Calcium type battery 14.9 +/-0.2 VDC
--LTO battery 14.0 +/-0.2 VDC
--LFP battery 14.5 +/-0.2 VDC
--Li-ion battery 12.6 +/-0.2 VDC
2-6 Absorption transits to Equalizing or Float condition:
--Charging current drops to 1.5 +/0.1 AMP
-- or Absorption charging timer timed out 4 Hour
2-7 Equalization charging active
--Only for WET or Calcium battery
--Battery voltage discharged to less than 10 +/-0.2 VDC
--Automatic equalizing charging periodical 28 Day
2-8
Equalization charging voltage at 25
15.5 +/-0.2 VDC
2-9 Equalization charging timer timed out 2 Hour
2-10
Float voltage (for Crystal, GEL, WET, Calcium, AGM battery) at 25
13.8 +/-0.2 VDC
Restart voltage for LTO battery 13.2 +/-0.2 VDC
Restart voltage for LFP battery 13.4 +/-0.2 VDC
Restart voltage for Li-ion battery 12.0 +/-0.2 VDC
2-11 Voltage control accuracy +/- 1%
2-12 Battery temperature compensation coefficient -24 mV/*C
2-13 Temperatur e compe nsation range
-20 ~ +50
3 Protection
3-1 Against reverse polarity or short circuit at panel or battery
3-2 No reverse current fr om battery to solar at night
3-3 Over temper ature protection during charging 65
4 Electrical parts
4-1 Input output terminal M5 terminals
5 Physical Parameters
5-1 Controller material Plastic, Standard ABS
5-2 Power te rminal maximum stranded wire size #6 AWG stranded-16 mm
2
5-3 Power te rminal torque Up to 17 in-lb (0.2n-m)
5-4 Mounting Vertical wall mounting
5-5 IP grade IP65,
5-6 Net weigh t Approx. 0.5KG
6 Environmenta l characteristics
6-1 Operating temperature
-25 ~ 50
/ -13~122
6-2 Storage temperature
-40 ~ 85 / -40~185
6-3 Operating Humidity range 100% no condensation
Voltage in below table are for 12V use, x 2 for 24V use.
Power Your Green Life!
Tel: +1- 626-575 7722 Cell: +1-213-820 6518 Fax: +1- 626-737 1140
Add: 4120 Valley Blvd, Walnut, CA 91789,USA
Email: sales@acopower.com Web:www.acopower.com