User Manual

1 Lead-acid battery
2 Lithium battery
Sealed(default)
Gel
Flooded
User
LiFePO4(4S/12V;8S/24V)
Li(NiCoMn)O2 (3S/12V;6S/24V)
User
CAUTION: When the default battery type is selected, the battery voltage
control parameters will be set by default and can’t be changed. To
change these parameters, select "User" battery type.
4.1.2 Battery Voltage Control Parameters
Lead-acid battery parameters
The parameters are in 12V system at 25 ºC, please double the values in 24V system.
Voltage
Battery type
Sealed Gel Flooded User
Over Voltage Disconnect Voltage 16.0V 16.0V 16.0V 917V
Charging Limit Voltage 15.0V 15.0V 15.0V 917V
Over Voltage Reconnect Voltage 15.0V 15.0V 15.0V 917V
Equalize Charging Voltage 14.6V —— 14.8V 917V
Boost Charging Voltage 14.4V 14.2V 14.6V 917V
Float Charging Voltage 13.8V 13.8V 13.8V 917V
Boost Reconnect Charging Voltage 13.2V 13.2V 13.2V 917V
Low Voltage Reconnect Voltage 12.6V 12.6V 12.6V 917V
Under Voltage Warning
Reconnect Voltage
Under Voltage Warning Voltage 12.0V 12.0V 12.0V 917V
Low Voltage Disconnect Voltage 11.1V 11.1V 11.1V 917V
Discharging Limit Voltage 10.6V 10.6V 10.6V 917V
Equalize Duration 120 min —— 120 min 0180 min
Boost Duration 120 min 120 min 120 min 10180 min
12.2V 12.2V 12.2V 917V
01 02 03 04 05 06 07
08 09 10 11 12 13 14 15 16
17
18 19 20 21 22 23 24 25 26 27
28 29 30 31 32 33 34 35 36