User Manual
1 Lead-acid battery
2 Lithium battery
Sealed(default)
Gel
Flooded
User
LiFePO4(4S/12V;8S/24V)
Li(NiCoMn)O2 (3S/12V;6S/24V)
User
CAUTION: When the default battery type is selected, the battery voltage
control parameters will be set by default and can’t be changed. To
change these parameters, select "User" battery type.
4.1.2 Battery Voltage Control Parameters
Lead-acid battery parameters
The parameters are in 12V system at 25 ºC, please double the values in 24V system.
Voltage
Battery type
Sealed Gel Flooded User
Over Voltage Disconnect Voltage 16.0V 16.0V 16.0V 9~17V
Charging Limit Voltage 15.0V 15.0V 15.0V 9~17V
Over Voltage Reconnect Voltage 15.0V 15.0V 15.0V 9~17V
Equalize Charging Voltage 14.6V —— 14.8V 9~17V
Boost Charging Voltage 14.4V 14.2V 14.6V 9~17V
Float Charging Voltage 13.8V 13.8V 13.8V 9~17V
Boost Reconnect Charging Voltage 13.2V 13.2V 13.2V 9~17V
Low Voltage Reconnect Voltage 12.6V 12.6V 12.6V 9~17V
Under Voltage Warning
Reconnect Voltage
Under Voltage Warning Voltage 12.0V 12.0V 12.0V 9~17V
Low Voltage Disconnect Voltage 11.1V 11.1V 11.1V 9~17V
Discharging Limit Voltage 10.6V 10.6V 10.6V 9~17V
Equalize Duration 120 min —— 120 min 0~180 min
Boost Duration 120 min 120 min 120 min 10~180 min
12.2V 12.2V 12.2V 9~17V