Battery and Load Wire Size
The battery and load wire size must conform to the rated current, the reference
size as below:
Model
Rated Charge
Current
Rated discharge
current
Battery wire size
Load wire
size
MY20
MY30
MY40
20A
30A
40A
20A
30A
40A
6mm /10AWG
10mm /8AWG
16mm /6AWG
2
2
2
6mm /10AWG
10mm /8AWG
16mm /6AWG
2
2
2
CAUTION: The wire size is only for reference. If there is a long distance
between the PV array and the controller or between the controller and
the battery, larger wires can be used to reduce the voltage drop and
improve performance.
CAUTION: For the battery, the recommended wire will be selected
according to the conditions that its terminals are not connected to any
additional inverter.
2.4 Mounting
WARNING: Risk of explosion! Never install the controller in a sealed
enclose with flooded batteries! Do not install in a confined area where
battery gas can accumulate.
WARNING: Risk of electric shock! When wiring the solar modules, the
PV array can produce a high open circuit voltage, so turn off the
breaker before wiring and be careful when wiring.
CAUTION:The controller requires at least 150mm of clearance above
and below for proper air flow. Ventilation is highly recommended if
mounted in an enclosure.