Full Product Manual
www.ACOPower.com
4120 Valley Blvd Walnut, CA 91789, USA
+1-626-737 1140
HY-PTK-100WPX20A
Voltage in below table are for 12V use, x 2 for 24V use.
6 Technical Specifications
--Li-ion battery 12.6 +/-0.2 VDC
2-6 Absorption transits to Equalizing or Float condition:
--Charging current drops to 1.5 +/0.1 AMP
-- or Absorption charging timer timed out 4 Hour
2-7 Equalization charging active
--Only for WET or Calcium battery
--Battery voltage discharged to less than
10
+/-0.2 VDC
--Automatic equalizing charging periodical 28 Day
2-8
Equalization charging voltage at 25
℃
15.5 +/-0.2 VDC
2-9 Equalization charging timer timed out 2 Hour
2-10
Float v
oltage (for Crystal, GEL, WET, Calcium, AGM battery) at 25℃
13.8 +/-0.2 VDC
Restart voltage for LTO battery 13.2 +/-0.2 VDC
Restart voltage for LFP battery 13.4 +/-0.2 VDC
Restart voltage for Li-ion battery 12.0 +/-0.2 VDC
2-11 Voltage control accuracy +/- 1%
2-12 Battery temperature compensation coefficient -24 mV/*C
2-13 Temperature compensation range -20 ~ +50
℃
3 Protection
3-1 Against reverse polarity or short circuit at panel or battery
3-2 No reverse current from b
attery to solar at night
3-3 Over temperature protection during charging 65
℃
4 Electrical parts
4-1 Input output terminal M5 terminals
5 Physical Parameters
5-1 Controller material Plastic, Standard ABS
5-2 Power terminal maximum stranded wire size #6 AWG stranded-16 mm
2
5-3 Power terminal torque Up to 17 in-lb (0.2n-m)
5-4 Mounting Vertical wall mounting
5-5 IP grade IP65,
5-6 Net weight Approx. 0.5KG
6
Environmental characteristics
6-1 Operating temperature
-25 ~ 50
℃
/ -13~122
℉
6-2 Storage temperature
-40 ~ 85℃ / -40~185 ℉
6-3 Operating Humidity range 100% no condensation