Removing and Replacing FRUs
B - 6
Username:admin
Password:acopia
minturnA>enable
minturnA#raidsilence
minturnA#...
Replacing the Disk Drive
To replace the disk drive, slide it into the empty slot. Then use a key to lock
the drive in place. Rotate the key counterclockwise until notch is pointing
up.
Incorporating the Disk into the RAID
To incorporate the disk into the RAID, use the raid rebuild command from
priv-exec mode:
raidrebuild{disk1|disk2}
where disk1 | disk2 specifies the disk to rebuild. The top disk is disk1.
For example, the following command rebuilds the upper disk:
minturnA#raidrebuilddisk1
minturnA#...
Removing and Replacing the Fan Tray
Remove the fan tray as described in Removing the Fan Tray, on page 6-7.
To replace the fan tray, reverse the steps. (The entire fan tray is the FRU, not
the individual fans.)
WARNING
After 60 seconds, a busy ARX
®
may overheat without its fan tray. An ARX
®
with a light traffic load can last much longer. In any case, have the
replacement fan tray ready before you remove a running fan tray from the
chassis.