Installation guide
Removing and Replacing a Disk Drive
ARX
®
6000 Hardware Installation Guide B - 5
2. Pull the handle (hinged) toward you and slowly slide the disk drive
out of the bay.
Important
The drives must be locked to achieve proper seating in the drive bay.
Figure B.2 Removing a Disk Drive
The chassis continues to run, in degraded state, with only one disk missing
from the RAID.
Silencing the RAID Alarm
After you remove the drive, an audible alarm goes off to signal that the drive
is missing. From the CLI (priv-exec mode), you can use the
raid silence
command to quiet this alarm:
raidsilence
For example, the following command sequence logs into a switch at
10.1.27.69, enters
enable to go to priv-exec mode, and silences the RAID
alarm:
$telnet10.1.27.69
Trying10.1.27.69...
Connectedto10.1.27.69.
Escapecharacteris'^]'.
Unlock key, then
pull handle
(hinged) out
toward you
Keys:
Notch up - drive
locked
Notch to the right