Installation guide
Booting the Switch
ARX
®
6000 Hardware Installation Guide 7 - 9
prtlndA(cfg)#showron
SwitchNameHAPeerSwitchUptime
StatusUUIDManagementAddr
‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐
bstnA(None)0days,02:07:57
ONLINEd9bdece8‐9866‐11d8‐91e3‐f48e42637d5810.1.1.7
gffstnA(None)0days,01:59:42
ONLINEe5d870ae‐571e‐1352‐916b‐ef324fbc05a210.1.49.60
minturnA(None)0days,02:00:16
OFFLINE3d17e8ce‐571e‐11dc‐9852‐ef323fbb290f10.1.27.69
provA(None)0days,02:08:11
ONLINE
db922942‐876f‐11d8‐9110‐8dtu78fc832910.1.38.19
prtlndAprtlndB0days,02:07:59
ONLINE876616f6‐79ac‐11d8‐946f‐958fcb4e6e3510.1.23.11
prtlndBprtlndA0days,00:18:55
ONLINE64dcab94‐a2b6‐11d8‐9d25‐bf2c991c83f910.1.23.12
prtlndA(cfg)#...
Applying the UUID
The next prompt in the initial-boot script asks for the UUID. Enter the
UUID of the failed switch. For example,
...
TheUUIDshouldonlybeenteredifthischassisisreplacingafailedchassis
andtheenteredUUIDshouldmatchtheUUIDofthefailedchassis.
11.Enterthechassis'sUUID
intheformat
xxxxxxxx‐xxxx‐xxxx‐xxxx‐xxxxxxxxxxxx.(default=d4ukjce8‐1854‐11d8‐91e3‐f48e42637d58)#
3d17e8ce‐571e‐11dc‐9852‐ef323fbb290f
...
Important
No two running chassis should ever share the same UUID. Only enter the
UUID in a switch-replacement scenario.
Installing a Redundant Peer or Cluster
If you are installing the second switch in a redundant pair (called an ARX
cluster) or if you are configuring a second ARX cluster in a Disaster
Recovery (DR) configuration, you need to provide additional information to
the initial-boot script. All members of the cluster share a common master
key.
Note
A master key is an encryption key for all critical-security parameters
(CSPs), such as administrative passwords.